Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE TIMKEN CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE TIMKEN CORPORATION in 2210 FRANKLIN STREET, CARLYLE, IL 62231 (NAICS 332991). OSHA activity number 346465339.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Timken Corporation — free Get an email when a new federal OSHA severe-injury report for The Timken Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2210 FRANKLIN STREET
City
CARLYLE
State
IL
ZIP
62231
Mailing
2210 FRANKLIN STREET, CARLYLE, IL 62231
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332991
Employees
23
Ownership type
A

1 citation on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2023
Abate by
Jun 21, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On and before April 4, 2023, the energy control (Lockout/Tagout) procedure for the CAR Breakdown Press, did not properly outline the steps for the control of the hazardous energy sources that would allow for effective verification. The CAR Breakdown Press procedure incorrectly directs the isolation of the electrical energy first and the pneumatic energy second. Electrical energy is needed to actuate the controls and pneumatic valves of the machine to verify that the pneumatic energy has been isolated and all potentially hazardous stored or residual pneumatic energy is relieved. After verifying the pneumatic energy control measures are effective, then the electrical energy should be isolated, locked out and verified.
Recent events (3)
  • — F (S) $0
  • — C (S) $11162
  • — Z (S) $11162

View The Timken Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346465339.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.