OSHA Inspection: MORTON BUILDINGS, INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MORTON BUILDINGS, INCORPORATED in 3370 YORK ROAD, GETTYSBURG, PA 17325 (NAICS 332311). OSHA activity number 346467418.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morton Buildings, Incorporated — free Get an email when a new federal OSHA severe-injury report for Morton Buildings, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
3370 YORK ROAD
City
GETTYSBURG
State
PA
ZIP
17325
Mailing
3370 YORK ROAD, GETTYSBURG, PA 17325
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
48
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 10 exposed
Issued
Jun 29, 2023
Abate by
Dec 1, 2023
Penalty
Initial $9,822 · Current $15,625
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees.  a) Building 3, On or about January 27, 2023 the door shop racking system was not anchored into the floor exposing employees to caught in and struck by hazards.   b) Building 3, On or about January 27, 2023 the door shop racking system had damaged upright stanchion's while still loaded, employees were exposed to caught in and struck by hazards.  c) Building 3, On or about January 27, 2023 the door shop rack system was not placarded with the weight rating, employees were exposed to caught in and struck by hazards.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $15625
  • — Z (S) $9822

1910.36 D01

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Jun 29, 2023
Abate by
Jul 14, 2023
Penalty
Initial $7,366 · Current $0 Reduced
29 CFR  1910.36(d)(1):Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a) Building 3, On or about January 27, 2023 the emergency exit discharge door at the live deck was locked from the inside with a slide lock, employees were exposed to hazards associated with emergency egress.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7366

1910.36 G02

Deleted Serious Gravity 1 1 instance 15 exposed
Issued
Jun 29, 2023
Abate by
Jul 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.36(g)(2):Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  a. In Building 1 - On or about January 27, 2023, employees were exposed to fire hazards due to impeded egress, the employees working on the back side of the Bradburt conveyor system, the egress rout past the motor was 20 inches.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 15 exposed
Issued
Jun 29, 2023
Abate by
Dec 1, 2023
Penalty
Initial $12,278 · Current $15,625
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Building 1, On or about January 27, 2023, employees were exposed to caught in hazards from unguarded in running nip point of the conveyor system on  Machine #: 111 Bradbury, Roll Former Model: D2.44.16 Serial Number: 10062.  b) Building 1, On or about January 27, 2023, employees were exposed to caught in and struck by hazards due to the safety interlock system being bypassed allowing entry into the caged areas while the system cycles on  Machine #: 106 Make: Bradbury Model: "Upender" Serial Number: 10058.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $15625
  • — Z (S) $12278

1910.212 A02

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Jun 29, 2023
Abate by
Jul 14, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(2):Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  a) Building 3, On or about January 27, 2023, the right side of Machine #: 315 Make: Purlin Machine, yellow guarding was not secured in a manner that required tooling or other means to defeat rendering the guarding ineffective, employees were exposed to caught in hazards.  b) Building 3, On or about January 27, 2023,  Machine #: 318 Make: Column Machine , guarding used a slide lock that required no tooling for access which allowed the guard to be defeated, employees were exposed to caught in hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 A09

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 29, 2023
Abate by
Dec 1, 2023
Penalty
Initial $9,822 · Current $0 Reduced
1910.213(a)(9):  All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requires of 1910.219:  a) Building 3, On or about January 27, 2023 the chain and sprocket at approximately waist height on Machine #: 315 Make: Purlin Machine, was not guarded to prevent employees from being exposed to caught in hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9822

1910.333 A

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jun 29, 2023
Abate by
Jul 14, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:   a) Building 3, On or about January 27, 2023, The employer did not establish electrically safe work practices and policies to ensure only qualified personnel were accessing the live parts of the Gordon Brake Monitor for Machine #: 303 Make: Mitek Roof Tracker Model: 63826-501-460v Serial Number: 06007273320.1A, and that the practices included the appropriate level of personal protective equipment and testing equipment.  Employees were making adjustments and resetting the brake monitor while energized with live electrical current greater than 50volt/AC, employees were exposed to electrical hazards.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 C02

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jun 29, 2023
Abate by
Jul 14, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.333(c)(2): The employer did not ensure that only qualified persons were allowed to work on energized circuit parts or equipment that had not been de-energized under the procedures of paragraph (b) of this section.  a) Building 3, On or about January 27, 2023, The employer did not ensure only qualified personnel were accessing the live parts of the Gordon Brake Monitor for Machine #: 303 Make: Mitek Roof Tracker Model: 63826-501-460v Serial Number: 06007273320.1A, employees were making adjustments and resetting the brake monitor while energized with live electrical current greater than 50volt/AC, employees were exposed to electrical hazards.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B02

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Jun 29, 2023
Penalty
Initial $9,822 · Current $3,750 Reduced
29 CFR  1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety:    a) Building 3, On or about January 27, 2023, Employees did not have electrical safe work practices training with topics including, but not limited to, ensuring that the door to the Gordon Brake Monitor for Machine#: 303 (Make: Mitek Roof Tracker Model: 63826-501-460v Serial Number: 06007273320.lA) was closed after making adjustments and resetting the brake monitor.  Corrected during the inspection.
Recent events (2)
  • — I (O) $3750
  • — Z (S) $9822

View Morton Buildings, Incorporated's full OSHA safety record →