FREEPORT, IL —
OSHA Inspection: IN GROWN FARMS LLC 2
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of IN GROWN FARMS LLC 2 in 3597 E. COLBY ROAD, FREEPORT, IL 61032 (NAICS 111419). OSHA activity number 346475734.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IN GROWN FARMS LLC 2
- Site address
- 3597 E. COLBY ROAD
- City
- FREEPORT
- State
- IL
- ZIP
- 61032
- Mailing
- 3597 E. COLBY ROAD, FREEPORT, IL 61032
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 111419
- Employees
- 126
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.157 G01
- Issued
- Jul 14, 2023
- Abate by
- Sep 15, 2023
- Penalty
- Initial $12,055 · Current $5,000 Reduced
0420
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting: (a) Green Waste Area - On or about February 1, 2023, the employer did not effectively train employees on portable fire extinguisher use thereby exposing employees to fire and related hazards. An employee was injured while using portable extinguishers to put out fires that resulted from an explosion. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $5000
- — Z (S) $12055
1910.305 A02 I
- Issued
- Jul 14, 2023
- Abate by
- Sep 15, 2023
- Penalty
- Initial $10,046 · Current $5,000 Reduced
0420
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners. Note: Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C). (a) Green Waste Area - On or about February 1, 2023, the employer permitted the use of temporary string lights as a substitute for permanent fixed lighting within the CONEX intermodal shipping container where flammable vapors accumulated. The string light power plug was removed, and the string light was spliced into a wall mounted outlet box where it could be operated by light switch thereby exposing employees to shock and fire hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $5000
- — Z (S) $10046
1910.305 B01
- Issued
- Jul 14, 2023
- Abate by
- Sep 15, 2023
- Penalty
- Initial $0 · Current $0
0420
General-duty citation text
29 CFR 1910.305(b)(1): Conductors entering boxes, cabinets, or fittings were not protected from abrasions, nor were openings through which conductors enter were effectively closed: (a) Green Waste Area - On or about February 1, 2023, the employer permitted the use of construction string lighting as a substitute for fixed lighting within the CONEX intermodal shipping container. Where the flexible power cord entered a wall mounted outlet box, strain relief, fittings, or other protections against abrasion were not implemented, thereby exposing employees to shock hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.307 B
- Issued
- Jul 14, 2023
- Abate by
- Sep 15, 2023
- Penalty
- Initial $14,063 · Current $10,000 Reduced
0420
General-duty citation text
29 CFR 1910.307(b): Areas designated as hazardous (classified) locations under the Class and Zone system and areas designated under the Class and Division system established after August 13, 2007 were not properly documented: (a) Green Waste Area - On or about February 1, 2023, the employer failed to classify a 40'x8'x8' intermodal shipping container (CONEX) as a hazardous location thereby exposing employees to explosion and fire hazards. The employer used the CONEX as enclosed, short-term storage for plant waste that had been saturated in butane. A spark was generated when an employee attempted to attach a portable space heater to an extension cord attached to an electrical outlet box mounted just inside the CONEX entrance. The electrical equipment provided was not rated for hazardous (classified) locations. The spark ignited flammable vapors and resulted in an explosion and fires within the CONEX. The CONEX and adjacent building were heavily damaged in the blast and the employee was hospitalized with burns to the hands and face. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $10000
- — Z (S) $14063
1910.307 C
- Issued
- Jul 14, 2023
- Abate by
- Sep 15, 2023
- Penalty
- Initial $14,063 · Current $10,000 Reduced
0420
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) Green Waste Area - On or about February 1, 2023, the employer failed to ensure that electrical equipment installed was approved for use inside an intermodal shipping container (CONEX), a designated hazardous location. The employer used the CONEX as enclosed, short-term storage for spent cannabis waste that had been saturated in butane. A spark was generated when an employee attempted to attach a portable space heater to an extension cord attached to an electrical outlet box mounted just inside the CONEX entrance. The electrical equipment provided was not rated for hazardous (classified) locations. The spark ignited flammable vapors and resulted in an explosion and fires within the CONEX. The CONEX and adjacent building were heavily damaged in the blast and the employee was hospitalized with burns to the hands and face. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $10000
- — Z (S) $14063
More inspections at In Grown Farms LLC 2
View In Grown Farms LLC 2's full OSHA safety record →
More inspections in this industry (NAICS 111419)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346475734.