Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: REYES BROTHERS CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REYES BROTHERS CONSTRUCTION LLC in 2076/2078 PINE GROVE LANE, COLUMBUS, OH 43232 (NAICS 238160). OSHA activity number 346485287.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reyes Brothers Construction LLC — free Get an email when a new federal OSHA severe-injury report for Reyes Brothers Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2076/2078 PINE GROVE LANE
City
COLUMBUS
State
OH
ZIP
43232
Mailing
32847 REDWOOD BLVD, AVON LAKE, OH 44012
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 3, 2023
Abate by
Apr 13, 2023
Penalty
Initial $3,683 · Current $3,683
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a. Located at apartments 2076 and 2078 Pine Grove Lane Columbus, Ohio, 43232: On or about February 6. 2023, employees were observed using a ladder to ascend and descend a single story roof of Pine Grove Apartments without 3 feet of the ladders side rails above the roof. Thereby exposing the employees to falls of approximately 9 feet 5 inches to the ground.
Recent events (1)
  • — Z (S) $3683

1926.102 A01

Repeat Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2023
Abate by
Apr 13, 2023
Penalty
Initial $7,367 · Current $7,367
29 CFR  1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a. Location at apartments 2076 and 2078 Pine Grove Lane Columbus Ohio, 43232: On or about February 06, 2023, the employer did not ensure the employees were protected from face or eye injury while installing roofing material using pneumatic nail guns. Thereby exposing the employees to struck by hazards to the eyes.  Reyes Brothers Construction LLC was previously cited for a violation of this Occupational Safety and Health standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 1304977, citation number 1, item number 1 and was affirmed as a final order on May 03, 2018, with respect to a workplace located at 19006 Blue Spruce Dr. STRONGSVILLE, OH 44149.
Recent events (1)
  • — Z (R) $7367

1926.501 B13

Repeat Gravity 5 1 instance 9 exposed
Issued
Apr 3, 2023
Abate by
Apr 13, 2023
Penalty
Initial $7,367 · Current $7,367
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  a. Location at apartments  2076 and 2078 Pine Grove Lane Columbus Ohio, 43232: On or about February 06, 2023, employees were performing roofing work from a single-story roof at Pine Grove Apartments without any type of fall protection which thereby exposed the employees to falls of approximately 9 foot 5 inches to the ground below.  Reyes Brothers Construction LLC was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1304977, citation number 1, item number 2 and was affirmed as a final order on May 03, 2018, with respect to a workplace located at 19006 Blue Spruce Dr, STRONGSVILLE, OH 44149.
Recent events (1)
  • — Z (R) $7367

View Reyes Brothers Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346485287.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.