LAKEWOOD, CO —
OSHA Inspection: HEART AUTOMOTIVE LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HEART AUTOMOTIVE LLC in 1557 YARROW STREET, LAKEWOOD, CO 80214 (NAICS 811111). OSHA activity number 346486491.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEART AUTOMOTIVE LLC
- Site address
- 1557 YARROW STREET
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80214
- Mailing
- 7801 W COLFAX AVE, LAKEWOOD, CO 80214
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.215 A04
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $4,687 · Current $2,344 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or before 2/7/23, the employer did not ensure that the work rest on the Bauer bench grinder was adjusted to no more than 1/8th of an inch maximum opening. This condition exposed employees to ingoing nip points and flying chips and sparks.
Recent events (2)
- — I (S) $2343.5
- — Z (S) $4687
1910.303 G01 II
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $4,687 · Current $2,344 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) On or before 2/7/23, the employer did not ensure that service panels rated 600 Volts or less had at least 30 inches of clearance. The area in front of the service panels had items stored within 30 inches of the panel. This condition exposed employees to electric shock and fire hazards.
Recent events (2)
- — I (S) $2343.5
- — Z (S) $4687
1910.303 G02 I
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) On or before 2/7/23, the employer did not ensure that the dead front of a live service panel was installed. This condition exposed employees to electric shock and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) On or before 2/7/23, the employer did not ensure that all electrical junction boxes and fittings were provided with covers. Electrical outlets and switches lacked covers throughout the automotive building. This condition exposed employees to electric shock and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": (a) On or before 2/7/23, the employer did not ensure that all exits were marked in accordance with this standard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) On or before 2/7/23, the employer did not ensure that all portable fire extinguishers were subjected to an annual maintenance check. Fire extinguishers were overdue for their annual maintenance checks. This condition exposed employees to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Heart Automotive LLC
View Heart Automotive LLC's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346486491.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.