OSHA Inspection: NOE CONTRERAS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NOE CONTRERAS in 268 BLUE HERON BLUFF, DAWSONVILLE, GA 30534 (NAICS 238130). OSHA activity number 346488851.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NOE Contreras — free Get an email when a new federal OSHA severe-injury report for NOE Contreras is published. One employer, no account, unsubscribe in one click.
Establishment
NOE CONTRERAS
Site address
268 BLUE HERON BLUFF
City
DAWSONVILLE
State
GA
ZIP
30534
Mailing
108 A RIDGEVIEW DRIVE, CUMMING, GA 30040
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 9 exposed
Issued
Apr 4, 2023
Penalty
Initial $2,009 · Current $2,009
29 CFR  1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) At 268 Blue Heron Bluff Dawsonville, GA 30534: On or about February 6, 2023, workers were exposed to struck-by hazards while performing framing operations below the upper working surface where tools such as but not limited to saws and pneumatic nail guns where in use, in that the employer did not enforce the wearing of head protection.
Recent events (1)
  • — Z (S) $2009

1926.102 A01

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 4, 2023
Penalty
Initial $2,679 · Current $2,679
29 CFR  1926.102(a)(1):Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a) At 268 Blue Heron Bluff Dawsonville, GA 30534: On or about February 6, 2023, workers were exposed to struck-by hazards hazards while performing framing operations with tools such as but not limited to circular saws and pneumatic nail guns, in that the employer did not require the use of eye protection.
Recent events (1)
  • — Z (S) $2679

1926.501 B13

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 4, 2023
Penalty
Initial $4,018 · Current $4,018
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a) At 268 Blue Heron Bluff Dawsonville, GA 30534: On or about February 6, 2023, the employer exposed employees to fall hazards of 16-feet, 5-inches to the lower ground level, in that a fall protection system was not provided to employees engaged in framing activities.
Recent events (1)
  • — Z (S) $4018

View NOE Contreras's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346488851.