OSHA Inspection: PONCE GENERAL CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PONCE GENERAL CONSTRUCTION LLC in 609 ST. FRANCS PARKWAY, GONZALES, LA 70737 (NAICS 238140). OSHA activity number 346489131.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ponce General Construction LLC — free Get an email when a new federal OSHA severe-injury report for Ponce General Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
609 ST. FRANCS PARKWAY
City
GONZALES
State
LA
ZIP
70737
Mailing
20075 LOUISIANA 36, COVINGTON, LA 70433
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 27, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.  On or about February 7, 2023, employees were performing masonry work on a scaffold that was not fully planked, leaving a space greater than 1 inch between the platform (planks) uprights.
Recent events (1)
  • — Z (S) $6250

1926.451 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 27, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation,  On or about February 7, 2023,  employees were performing masonry work on a scaffold with no base plates.
Recent events (1)
  • — Z (S) $6250

1926.451 C03

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 27, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and/or uprights were not plumb and braced to prevent swaying and displacement.  On or about February 7, 2023,  employees were performing masonry work outside a building utilizing scaffolding on a scaffold that was not plumb, square, or level.
Recent events (1)
  • — Z (S) $6250

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 27, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffolds, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access.  On or about February 7, 2023,  Employees performing masonry work on the north side of the site ascended and descended the scaffold by utilizing the scaffold's bracing and frame to work at a height greater than two feet above a lower level. The scaffold lacked an appropriate means of access.
Recent events (1)
  • — Z (S) $6250

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $3,572 · Current $3,572
29 CFR  1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  On or about February 7, 2023,  employees performed masonry work on the exterior of the building at a height greater than ten feet from a scaffold with no guardrail system and no fall protection.
Recent events (1)
  • — Z (S) $3572

View Ponce General Construction LLC's full OSHA safety record →