Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. AIR FORCE 60TH MAINTENANCE SQUADRON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. AIR FORCE 60TH MAINTENANCE SQUADRON in 350 RAGSDALE ST. BLDG. 803, TRAVIS AFB, CA 94535 (NAICS 928110). OSHA activity number 346490485.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. AIR Force 60TH Maintenance Squadron — free Get an email when a new federal OSHA severe-injury report for U.S. AIR Force 60TH Maintenance Squadron is published. One employer, no account, unsubscribe in one click.
Site address
350 RAGSDALE ST. BLDG. 803
City
TRAVIS AFB
State
CA
ZIP
94535
Mailing
400 BRENNAN CIRCLE, TRAVIS AFB, CA 94535
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
50
Ownership type
D

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 14, 2023
Abate by
Jun 12, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Maintenance Squadron, Fabrication Flight ATM Shop: The Delta 20 inch drill press ( unknown serial number) was  not provided with a chuck guard. Employees were exposed to point of operation and flying debris hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Other-than-serious 1 instance 1 exposed
Issued
Apr 14, 2023
Abate by
Jun 12, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  Maintenance Squadron, Fabrication Flight ATM Shop: The plug end of the commercial pedestal fan (brand Air Master Fans) electrical cord was missing its grounding prong. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View U.S. AIR Force 60TH Maintenance Squadron's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346490485.