FALL RIVER, MA —
OSHA Inspection: SKYLINE COMPOSITE, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SKYLINE COMPOSITE, INC. in 63 WATER STREET, FALL RIVER, MA 02721 (NAICS 325211). OSHA activity number 346503170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SKYLINE COMPOSITE, INC.
- Site address
- 63 WATER STREET
- City
- FALL RIVER
- State
- MA
- ZIP
- 02721
- Mailing
- 63 WATER STREET, BUILDING #2, FALL RIVER, MA 02721
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 65
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.22 A01
- Issued
- Aug 9, 2023
- Abate by
- Sep 28, 2023
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: Facility, Cutting Booth: When workers were cutting and grinding on finished gel-coated articles a voluminous amount of explosive dust was created that coated the floor, objects in the booth, and pipes located above the work area. The employer did not clean up the accumulated dust on a regular basis, presenting an increased potential for fire and/or explosion in the event an ignition source occurs in the booth.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.107 B05 I
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $10,938
General-duty citation text
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute and there were no visible gauges, audible alarms or pressure activated devices installed in paint spray booth to indicate or insure that the required air speed was maintained: Production Area: 1) The average air speed over the open face of both the Front Shell Booth and the Roof Booth was less than 100 linear feet per minute; 2) Both the Front Shell Booth and the Roof Booth Booth were lacking visible gauges, audible alarms , or pressure-activated devices that would indicate or insure that the required air velocity in each booth was being maintained.
Recent events (2)
- — I (S) $10938
- — Z (S) $10938
1910.107 B05 IV
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv):Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: Production Area, Front Shell Booth and Roof Booth: The space both upstream and downstream of the filters are not protected with approved automatic sprinklers.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.107 G02
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: Facility, Front Shell Booth and Roof Booth: The employer did not ensure that the booths were as free as practical from the accumulation of combustible deposits from the chop spraying operation.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.132 F01 III
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $10,938
General-duty citation text
29 CFR 1910.132(f)(1)(iii):Employee(s) required to use PPE by this section were not trained to know how to don, doff, adjust, and wear PPE: Facility: When a worker was conducting a chop gun operation involving an application of Styrene and fiberglass, Personal Protective Equipment (PPE) was regularly worn in an inappropriate manner. The worker wore a Tyvek suit pulled down to the waist, leaving the face, neck, and arms exposed to airborne Styrene vapors and fiberglass particles.
Recent events (2)
- — I (S) $10938
- — Z (S) $10938
1910.134 D01 I
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability: In the following instances employees were not furnished with appropriate respiratory protection against the hazards to which they were exposed: 1) Cutting Booth: Employees conducting cutting and grinding of completed bus shell articles wore half-mask elastomeric respirators with the incorrect cartridges to protect them. The workers wore organic vapor cartridges instead of HEPA cartridges as protection against the hazards of respirable particulates; 2) Front Shell Booth: An employee involved in Chop Gun operations and layup cleaning activities wore respirator cartridges that protected only against organic vapors. Because the activities generated both organic vapors and particulates the proper cartridges to wear would be combination cartridges that simultaneously protect against both hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.134 G01 I A
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A):Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: Facility: Front Shell Booth and Roof Booth: Employees required to wear half-mask elastomeric respirators while conducting lay-up operations wore the masks with facial hair that came between the sealing surface of the facepiece and the user's face.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.134 G01 I B
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(B):Respirators with tight-fitting facepieces were worn by employees with a condition that interfered with the face-to-facepiece seal or valve function: Facility: Employees conducting chop gun operations, lay-operations, and sanding and buffing operations wore painter's spray socks over their head and face against overspray. However, these workers wore their tight-fitting respirators on top of the spray sock. This prevents a proper face-to-facepiece seal and greatly reduces the effectiveness of the respirator's protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: Facility: Workers required to wear respiratory protection during Chop Gun and Lay-up operations did not store their masks appropriately when not in use.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.134 K01
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not ensure that each employee can demonstrate knowledge of at least the following: (i) Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator; (ii) What the limitations and capabilities of the respirator are; (iii) How to inspect, put on and remove, use, and check the seals of the respirator; (iv) What the procedures are for maintenance and storage of the respirator: Facility: In the following instances, the employer did not ensure that each employee could demonstrate knowledge of the necessity of proper fit, usage, and maintenance of respirators, the limitations and capabilities of the respirator, how to inspect, don, doff, and seal check respirators, and the proper procedures for maintenance and storage of respirators: 1) Several workers were observed wearing half-mask elastomeric respirators with excessive facial hair, preventing a proper face-to-facepiece seal. This allowed workers to ingest and inhale toxic styrene vapors and explosive gel-coated dust; 2) Workers performing grinding of gel-coated fiberglass articles and performing buffing operations wore ineffective organic vapor cartridges instead of HEPA filters as protection against the explosive dust generated; 3) No worker was seen performing user check seals of their half-mask elastomeric respirator or full face respirator upon donning, to ensure the respirator had a proper face-to-facepiece seal; 4) Full face elastomeric respirators worn by workers conducting fiberglass lay-up operations were stored uncovered shop, and left uncovered inside the Front Shell booth during Lay-Up curing operations;
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.134 L01
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(l)(1): Evaluations of the workplace were not conducted to ensure the written respiratory protection program was being effectively implemented: Facility: The employer did not conduct adequate evaluations of the workplace to ensure that the company's written respiratory protection program was being effectively implemented.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.303 B02
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $10,938
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Facility: In the following locations electrical equipment was not installed and used in accordance with the instructions included in the listing and labelling in that, elecgrical boxes were subject to accumulations of combustible dusts and flammable vapors: Cutting Booth: The electrical box located just outside of the booth were not rated to prevent the accumulation of combustible dusts inside the box and onto unprotected electrical components. Roof Booth: The electrical box located just outside the Roof Booth where fiberglass lay-up operations occurred was not rated to prevent the entry and accumulation of flammable vapors inside the box and onto unprotected electrical components.
Recent events (2)
- — I (S) $10938
- — Z (S) $10938
1910.303 B07 I
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i):Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: Facility: In the following locations, unused openings in electrical boxes were not effectively closed to prevent the entry of flammable and combustible materials: Cutting Booth: The electrical box located just outside of the booth had unused openings that would allow combustible dusts to accumulate inside the box and onto unprotected electrical components. Roof Booth: The electrical box located just outside the Roof Booth where fiberglass lay-up operations occurred had unused openings that would allow flammable vapors to enter and accumulate inside the box. In addition this box and the unused openings were exposed to the accumulation of combustible dusts from the adjacent Cutting Booth which adds to the hazard. The electrical components inside this box were unprotected against both the vapors and combustible dusts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C02 I
- Issued
- Aug 9, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the class of location: Facility: In the following locations, electrical equipment in hazardous locations was not approved for the class of location: Roof Booth: The electrical box located just outside the Roof Booth where fiberglass lay-up operations occurred was not rated to prevent the entry and accumulation of flammable vapors inside the box and onto unprotected electrical components. Because of these conditions, this location is considered a Class I, Division 1 location; Cutting Booth: The electrical box located just outside of the booth were not rated to prevent the accumulation of combustible dusts inside the box and onto unprotected electrical components. Because of these conditions this location is considered a Class II, Division 2 location;
Recent events (2)
- — I (S) $0
- — Z (S) $10938
More inspections at Skyline Composite, INC.
View Skyline Composite, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346503170.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.