FALL RIVER, MA —
OSHA Inspection: SKYLINE COMPOSITE, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SKYLINE COMPOSITE, INC. in 63 WATER STREET, BUILDING #2, FALL RIVER, MA 02721 (NAICS 325211). OSHA activity number 347106932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SKYLINE COMPOSITE, INC.
- Site address
- 63 WATER STREET, BUILDING #2
- City
- FALL RIVER
- State
- MA
- ZIP
- 02721
- Mailing
- 63 WATER STREET, BUILDING #2, FALL RIVER, MA 02721
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 65
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- May 13, 2024
- Abate by
- Feb 3, 2025
- Penalty
- Initial $8,067 · Current $3,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm, including severe bums, to employees in that employees were exposed to fire, flash fire, deflagration, or explosion hazards from unvented dust collectors located inside a building. Production Area: Dust collectors including, but not limited to those listed below, were not equipped with explosion protection system and were located inside the facility. (a) Storage/Electrical Equipment Room - two Dantherm (Nederman) dust collectors that collected combustible fiberglass resin dust from the Robot (cutting) Room were not equipped with an explosion protection system and were located inside the room used for storage adjacent to the Robot (cutting) Room. (b) Cutting Area - left side Donaldson Torit dust collector that collected combustible fiberglass resin dust from the Cutting Booth was not equipped with an explosion protection system and was located inside the production area. (c) Cutting Area - right side Donaldson Torit dust collector that collected combustible fiberglass resin dust from the Cutting Booth was not equipped with an explosion protection system and was located inside the production area.
Recent events (2)
- — I (S) $3000
- — Z (S) $8067
1910.22 A01
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $8,067 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. Production Area: Where combustible dust generated by the manufacturing of fiberglass products was present, the work area was not kept clean. a) Robot Room - The area where fiberglass cutting was performed had explosible fiberglass dust located on the ventilation ducts near the ceiling, electrical raceways and pneumatic pipes along the walls, wall ledges and process equipment on or about November 29, 2023. b) Storage Room adjacent to the Robot Room - The area where fiberglass cutting was performed had explosible fiberglass dust located on the electrical equipment such as 480-volt circuit panels, raceways along the walls, two dust collectors for the Robot Rooms, and other process and general use electrical equipment and work surfaces on or about November 29, 2023. c) Cutting Booth - The area where fiberglass cutting was performed had explosible fiberglass dust located on the electrical raceways along the walls, process equipment and work surfaces on or about November 29, 2023.
Recent events (2)
- — I (S) $3000
- — Z (S) $8067
1910.106 E02 II
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $4,839 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii): Flammable and/or combustible liquid(s) were not stored in tanks or closed container(s): Production Area: Adjacent to the Gelcoat/High Volume Spray Room, there were open 55-gallon drums of Gelcoat Resin Adhesive (a flammable liquid) that was used for spray coating fiberglass resin parts.
Recent events (2)
- — I (S) $1000
- — Z (S) $4839
1910.107 G02
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: Production Area: The filters in the following spray rooms had heavy accumulation of combustible residue where employees spray fiberglass resin gelcoat: a) Gelcoat/High Volume Spray Room. b) Top Coat (Left) Spray Room.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G03
- Issued
- May 13, 2024
- Abate by
- Oct 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 910.107(g)(3): Approved metal waste cans were not provided wherever rags or waste were impregnated with finishing/flammable material; and all such rags or waste were not deposited therein immediately after use. The contents of waste cans were not properly disposed of at least once daily or at the end of each shift: Adjacent to Topcoat Spray Room: An open 55-gallon drum used for disposal of combustible debris such as rags impregnated with combustible residue was not approved i.e. closed container.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $4,839 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): Employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Production Area: Employer did not provide a medical evaluation to each employee who wore tight-fitting and half and full-face respirators for protection against respiratory hazards including solvents such as styrene when performing spraying of fiberglass glass resin and particulate from cutting operations.
Recent events (2)
- — I (S) $1000
- — Z (S) $4839
1910.134 D01 III
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): Employer did not identify and evaluate the respiratory hazard(s) in the workplace that included a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH: Chopping Booths: Employer did not identify and evaluate the respiratory hazards including, but not limited to, styrene where employees perform spraying of fiberglass glass resin in open booths.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H01
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer: Spray Booths Area: Employer did not provide respirator cleaning supplies to employees who wore tight fitting respirators for protection against contaminants such as styrene during fiberglass resin spraying operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $6,453 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: Storage (Electrical) Room: A 208 volt disconnect that energized Becker oil-less pumps was not effectively closed.
Recent events (2)
- — I (S) $2000
- — Z (S) $6453
1910.305 G02
- Issued
- May 13, 2024
- Abate by
- Feb 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Cutting Booth Area: A junction box mounted to the Donaldson Torit Dust Collector did not provide adequate strain relief to a joint between the junction box and the raceway/conduit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- May 13, 2024
- Abate by
- Feb 3, 2025
- Penalty
- Initial $8,067 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: Production Area: Where combustible dust generated by the manufacturing of fiberglass products was present, electrical equipment were not intrinsically safe, approved for a Class II, Division I, location, or safe for a Class II, Division I, location, on or about November 29, 2023: (a) Robot (cutting) Room - Electrical equipment including, but not limited to, normal lighting snap switches and overhead lighting were located were not intrinsically safe, approved for a Class II, Division I, location, or safe for a Class II, Division I, location, on or about November 29, 2023. (b) Storage (electrical equipment) Room adjacent to the Robot (cutting) Room - Electrical equipment including, but not limited to, overhead lights, circuit breaker panels, disconnect switches and outlets, in Class II, Division I, locations, was not intrinsically safe, approved for a Class II, Division I, or safe for a Class II, Division I, location, on or about November 29, 2023. (c) Robot (cutting) Room and Cutting Booth - A vacuum used in a Class II, Division 1 location was not intrinsically safe, approved for a Class II, Division 1, location, or safe for a Class II, Division 1, location on or about November 29, 2023. d) Adjacent to Cutting Booth - electrical equipment used to energize the Donaldson Torit dust collectors and other electrical equipment attached to the right Donaldson Torit dust collector to energize equipment such as the hoist/lift was not intrinsically safe, approved for a Class II, Division 1, location, or safe for a Class II, Division 1, location on or about November 29, 2023.
Recent events (2)
- — I (S) $2000
- — Z (S) $8067
1904.41 A02
- Issued
- May 13, 2024
- Abate by
- Jul 3, 2024
- Penalty
- Initial $1,613 · Current $0 Reduced
General-duty citation text
29 CFR 1904.41(a)(2): Employer (establishment) that had 20 or more employees but fewer than 250 employees at any time during the previous calendar year and was classified in an industry listed in appendix A to subpart E of this part, did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form: Located at the Skyline Composite on Water Street in Fall River, MA: On or about April 12, 2024, the employer failed to electronically submit information from their calendar year 2023 OSHA Form 300A or equivalent by 03/02/2024. The establishment employed 65 employees and was classified under industry NAICS 325211-Plastics Material and Resin Manufacturing during calendar year 2023.
Recent events (2)
- — I (O) $0
- — Z (O) $1613
More inspections at Skyline Composite, INC.
View Skyline Composite, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347106932.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.