Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPT. OF INTERIOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT. OF INTERIOR in 1800 LITTLE RIVER ROAD, FLAT ROCK, NC 28731 (NAICS 928110). OSHA activity number 346509169.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of Interior — free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of Interior is published. One employer, no account, unsubscribe in one click.
Site address
1800 LITTLE RIVER ROAD
City
FLAT ROCK
State
NC
ZIP
28731
Mailing
1800 LITTLE RIVER ROAD, FLAT ROCK, NC 28731
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
12
Ownership type
D

7 citations on file for this inspection.

1910.22 B

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.22(b):(b) Loads.  The employer must ensure that each walking-working surface can support the maximum intended load for that surface.  Employees did not know the intended load limit for the mezzanine level, which was being used for storage.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2):Each exit must be clearly visible and marked by a sign reading "Exit."  Exit doors were not clearly marked exposing employees to entrapment and fire hazards in the event of a fire.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.215(b)(9): 29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.   Employees were exposed to a struck by hazard while working with a Delta 8 inch bench grinder that was missing a guard on its left side.
Recent events (1)
  • — Z (S) $0

1910.303 B08 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(8)(i):Electric equipment shall be firmly secured to the surface on which it is mounted. Note to paragraph (b)(8)(i) of this section: Wooden plugs driven into holes in masonry, concrete, plaster, or similar materials are not considered secure means of fastening electric equipment.  Employer did not ensure multiple 208v electrical panel were firmly secured.
Recent events (1)
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.304(g)(5):Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.  The path to ground for a 25ft. extension cord was missing the ground pin and was not permanent, continuous and effective.
Recent events (1)
  • — Z (S) $0

1910.305 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(i):Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.  A junction box used to service lights and other equipment, was missing a knockout plug.
Recent events (1)
  • — Z (S) $0

1910.1200 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(6):Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:  Employer did not ensure the spray bottle was properly labeled.
Recent events (1)
  • — Z (S) $0

View U.S. Dept. of Interior's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346509169.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.