OSHA Inspection: CRESCO LABS, LLC

Monitoring inspection · Health discipline

On , OSHA opened a monitoring health inspection of CRESCO LABS, LLC in 19042 US HWY 19, CLEARWATER, FL 33764 (NAICS 453998). OSHA activity number 346520356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cresco Labs, LLC — free Get an email when a new federal OSHA severe-injury report for Cresco Labs, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CRESCO LABS, LLC
Site address
19042 US HWY 19
City
CLEARWATER
State
FL
ZIP
33764
Mailing
400 W. ERIE STREET SUITE 300, CHICAGO, IL 60654
Inspection type
Monitoring (D)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
7
Ownership type
A

3 citations on file for this inspection.

1910.303 G01

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Mar 9, 2023
Penalty
Initial $6,696 · Current $0 Reduced
29 CFR 1910.36(d)(1):Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  (a)  At 19042 US Hwy 19, Clearwater, FL 33764, In the breakroom area near the employee timeclock: On or about February 22, 2023, employees were exposed to fire and entrapment hazards, in that the door leading to the exit route in the break area was obstructed by a sliding bar style door lock preventing prompt access to the exit in the event of an emergency.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6696

1910.36 D01

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 9, 2023
Penalty
Initial $6,696 · Current $13,392
29 CFR 1910.36(d)(1):Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  (a)  At 19042 US Hwy 19, Clearwater, FL 33764, In the breakroom area near the employee timeclock: On or about February 22, 2023, employees were exposed to fire and entrapment hazards, in that the door leading to the exit route in the break area was obstructed by a sliding bar style door lock preventing prompt access to the exit in the event of an emergency.
Recent events (2)
  • — I (S) $13392
  • — Z (S) $6696

1910.157 C01

Other-than-serious 4 instances 5 exposed
Issued
Mar 9, 2023
Abate by
Mar 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) At 19042 US Hwy 19, Clearwater, FL 33764, in the lobby area: On or about February 22, 2023, employees were exposed to fire and entrapment hazards, in that the fire extinguisher in the lobby area was not clearly identified allowing prompt access to fire extinguishers in the event of an emergency.  (b) At 19042 US Hwy 19, Clearwater, FL 33764, in the showroom/ dispensary area: On or about February 22, 2023, employees were exposed to fire and entrapment hazards, in that the fire extinguisher in the main showroom/dispensary  area was  not clearly identified allowing prompt access to fire extinguishers in the event of an emergency.  (c) At 19042 US Hwy 19, Clearwater, FL 33764, in the employee break area area: On or about February 22, 2023, employees were exposed to fire and entrapment hazards, in that the fire extinguisher in the breakroom/ timeclock area was  not clearly identified allowing prompt access to fire extinguishers in the event of an emergency.  (d) At 19042 US Hwy 19, Clearwater, FL 33764, in the vault entrance area: On or about February 22, 2023, employees were exposed to fire and entrapment hazards, in that the fire extinguisher in the hallway, near the vault entrance was  not clearly identified allowing prompt access to fire extinguishers in the event of an emergency.