Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PATRIOT BEVERAGES, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PATRIOT BEVERAGES, LLC in 20 HARVARD ROAD, LITTLETON, MA 01460 (NAICS 312112). OSHA activity number 346552839.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Patriot Beverages, LLC for free Get an email when a new federal OSHA severe-injury report for Patriot Beverages, LLC is published. One employer, no account, unsubscribe in one click.
Site address
20 HARVARD ROAD
City
LITTLETON
State
MA
ZIP
01460
Mailing
20 HARVARD ROAD, LITTLETON, MA 01460
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312112
Employees
110
Ownership type
Private (A)

2 citations on file for this inspection.

1910.95 G01

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Jun 16, 2023
Abate by
Sep 18, 2023
Penalty
Initial $14,063 · Current $0 Reduced

Hazardous substances 8111

29 CFR  1910.95(g)(1):The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:  Location - Filler room  On or about May 25, 2023, an employee was exposed to noise levels exceeding the 8-hour time-weighted average (TWA) of 85 dBA while working in the Filler room. The employee was exposed to a continuous noise level of 91.0 dBA as an 8-hour Time-Weighted Average (TWA), which was equivalent to 115.2% of the permissible daily noise exposure during 375 minutes sampling period. The employee had not received an audiometric test.
Recent events (2)
  • · I (S) $0
  • · Z (S) $14063

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 16, 2023
Penalty
Initial $14,063 · Current $7,000 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Location -production area (A line)  On or about March 6, 2023, employees were exposed to rotating parts, point of operation, and flying chip hazards that were not guarded.  The box folding machine in the A line was not guarded on Wallingford, model number PF01-007.
Recent events (2)
  • · I (S) $7000
  • · Z (S) $14063

View Patriot Beverages, LLC's full OSHA safety record →