On , OSHA opened a planned safety inspection of ISJ UNDERGROUND UTILITIES LLC in 7506 SPRING CYPRESS RD., SPRING, TX 77379 (NAICS 237110). OSHA activity number 346581895.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ISJ Underground Utilities LLC — free Get an email when a new federal OSHA severe-injury report for ISJ Underground Utilities LLC is published. One employer, no account, unsubscribe in one click.
Site address
7506 SPRING CYPRESS RD.
City
SPRING
State
TX
ZIP
77379
Mailing
526 SOUTH PINE STREET, ROSHARON, TX 77583
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.651 I01

Serious Gravity 5 1 instance 7 exposed
Issued
May 9, 2023
Penalty
Initial $7,813 · Current $4,688 Reduced
29 CFR  1926.651(i)(1):Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees.  On or about March 22, 2023, employees were exposed to struck-by hazards for a portion of a cement curb that was undercut above the excavation.
Recent events (2)
  • — I (S) $4687.8
  • — Z (S) $7813

1926.651 J02

Serious Gravity 5 1 instance 7 exposed
Issued
May 9, 2023
Penalty
Initial $7,813 · Current $4,688 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.   On or about March 22, 2023, employees working in an excavation were exposed to a crushed-by hazard from the excavator which was not at least 2 feet from the edge of the excavation.
Recent events (2)
  • — I (S) $4687.8
  • — Z (S) $7813

1926.652 C

Serious Gravity 5 1 instance 7 exposed
Issued
May 9, 2023
Penalty
Initial $7,813 · Current $4,688 Reduced
29 CFR 1926.652(c):  Support systems, shield systems, and other protective systems were not designed and constructed in accordance with the requirements of paragraph (c)(1-4); as applicable    On or about March 22, 2023 employees were exposed to cave-in hazards while working in an excavation that did not have an adequate protective system in place.