OSHA Inspection: ENERSTAR RENTALS & SERVICES, LTD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENERSTAR RENTALS & SERVICES, LTD in CACTUS RIG #168 4.5 MILS N DIRECTION FROM PECOS, PECOS, TX 79772 (NAICS 532120). OSHA activity number 346618283.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Enerstar Rentals & Services, LTD — free Get an email when a new federal OSHA severe-injury report for Enerstar Rentals & Services, LTD is published. One employer, no account, unsubscribe in one click.
Site address
CACTUS RIG #168 4.5 MILS N DIRECTION FROM PECOS
City
PECOS
State
TX
ZIP
79772
Mailing
#110,516 - 3RD ST SE
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
532120
Employees
2
Ownership type
A

5 citations on file for this inspection.

1910.303 B07 IV

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
May 16, 2023
Penalty
Initial $6,026 · Current $6,000 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action or overheating.     On or about April 4, 2023, at the Cactus Rig # 168 drill site, a broken electrical receptacle located outside the command center exposed employees to an electrical shock hazard.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $6026

1910.334 A03 I

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
May 16, 2023
Penalty
Initial $6,026 · Current $0 Reduced
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor.  On or about April 4, 2023, at the Cactus Rig # 168 drill site, a flexible cord outside the command center was installed without a grounding pin. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6026

1910.305 A02 X

Deleted Other-than-serious 1 instance 2 exposed
Issued
May 16, 2023
Penalty
Initial $1,128 · Current $0 Reduced
29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.   On or about April 4, 2023, at Cactus Rig # 168 drill site, a yellow extension cord located outside the command center was ran and pinched under a metal door without protection from accidental damage. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1128

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
May 16, 2023
Abate by
May 26, 2023
Penalty
Initial $1,128 · Current $1,000 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about April 4, 2023, at the Cactus Rig # 168 drill site, the electrical box (120/240V) located on the mud man's trailer did not have the proper bushing for the black power cable. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1128

1910.305 J02 V

Other-than-serious 1 instance 2 exposed
Issued
May 16, 2023
Abate by
May 26, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered:  On or about April 4, 2023, at the Cactus Rig # 168 drill site, an outdoor receptacle outside the command center did not have a cover and was not protected from weather.  This condition exposed employees electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Enerstar Rentals & Services, LTD's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346618283.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.