KANSAS CITY, MO —
OSHA Inspection: STONE MOUNTAIN MANUFACTURING LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of STONE MOUNTAIN MANUFACTURING LLC in 1248 CRYSTAL AVENUE, KANSAS CITY, MO 64126 (NAICS 327991). OSHA activity number 346621527.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STONE MOUNTAIN MANUFACTURING LLC
- Site address
- 1248 CRYSTAL AVENUE
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64126
- Mailing
- 10583 LACKMAN ROAD, LENEXA, KS 66219
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.178 L01 II
- Issued
- Sep 26, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $2,679 · Current $1,875 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer did not ensure that each operator had successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5): At the worksite located at 1248 Crystal Avenue, Kansas City, Missouri: Employees were exposed to struck by hazards from powered industrial trucks. Employees were permitted to operate powered industrial trucks prior to the completion of training and evaluation.
Recent events (2)
- — I (S) $1875.3
- — Z (S) $2679
1910.178 L02 II
- Issued
- Sep 26, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace: At the worksite located at 1248 Crystal Avenue, Kansas City, Missouri: Employees were exposed to struck by hazards from powered industrial trucks. Powered industrial truck operators were not presented training on forklifts in either video form or classroom lecture/discussion form. Powered industrial truck operators have not been evaluated by the employer in use of forklifts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- Sep 26, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): At the worksite located at 1248 Crystal Avenue, Kansas City, Missouri: Employees were exposed to struck by hazards from powered industrial trucks. Employees were not certified by the employer to operate powered industrial trucks prior to operating.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 I
- Issued
- Sep 26, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $4,688 · Current $3,282 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater: At the worksite located at 1248 Crystal Avenue, Kansas City, Missouri: Employees were exposed to serious shock, burn and or electrocution injuries. 1. In the welding area, electrical breaker panels were blocked by shelving, tools, and materials. 2. In the manufacturing area, live electrical breaker panels were blocked by shelving, tools, and materials such as wooden boards and buckets of compound. 3. In the manufacturing area, live electrical breaker panels were blocked by scaffolding and wooden boards.
Recent events (2)
- — I (S) $3281.6
- — Z (S) $4688
1910.303 G02 I
- Issued
- Sep 26, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $4,688 · Current $3,282 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Exposed live electrical parts were not protected from accidental contact by an approved enclosure. At the worksite located at 1248 Crystal Avenue, Kansas City, Missouri: Employees were exposed to serious shock, burn and or electrocution injuries. 1. On the west wall in the manufacturing area, electrical equipment operating at 50 volts, or more was not enclosed to protect from accidental contact due to the electrical cabinet door being left open. 2. On the north wall in the manufacturing area, electrical equipment operating at 50 volts, or more was not enclosed to protect from accidental contact due to the electrical cabinet door being left open.
Recent events (2)
- — I (S) $3281.6
- — Z (S) $4688
1910.305 G01 IV A
- Issued
- Sep 26, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $4,688 · Current $3,282 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: At the worksite located at 1248 Crystal Avenue, Kansas City, Missouri: Employees were exposed to shock, burn, and or electrocution hazards when temporary cords were used in lieu of fixed wiring.
Recent events (2)
- — I (S) $3281.6
- — Z (S) $4688
1910.305 G01 IV D
- Issued
- Sep 26, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: At the worksite located at 1248 Crystal Avenue, Kansas City, Missouri: Employees were exposed to serious shock, burn and or electrocution injuries when extension cords were attached to building structures.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Stone Mountain Manufacturing LLC
View Stone Mountain Manufacturing LLC's full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346621527.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.