WENTZVILLE, MO —
OSHA Inspection: CM EXTERIORS LLC
Special Programs inspection · Safety discipline
At a glance
On , OSHA opened a special Programs safety inspection of CM EXTERIORS LLC in LOT 100 AMBERLEIGH MANOR DR, WENTZVILLE, MO 63385 (NAICS 238170). OSHA activity number 346640824.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CM EXTERIORS LLC
- Site address
- LOT 100 AMBERLEIGH MANOR DR
- City
- WENTZVILLE
- State
- MO
- ZIP
- 63385
- Mailing
- 24 DANIEL DRIVE, WENTZVILLE, MO 63385
What kind of inspection was it?
- Inspection type
- Special Programs (K)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 8
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.451 B07
- Issued
- Aug 25, 2023
- Penalty
- Initial $3,349 · Current $335 Reduced
General-duty citation text
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap did not occur over a support. On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. Part of this scaffold had overlapped platforms to create a long platform and this overlap did not occur over a support.
Recent events (2)
- — I (S) $334.9
- — Z (S) $3349
1926.451 B10
- Issued
- Aug 25, 2023
- Penalty
- Initial $4,688 · Current $469 Reduced
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were intermixed with force so as to distort the scaffold's structural integrity: On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. The fabricated half of the scaffold relied on an A-frame step ladder for support. This ladder did not have a metal spreader or locking device to lock the device in position while the device was in use, thus affecting the scaffolds structural integrity.
Recent events (2)
- — I (S) $468.8
- — Z (S) $4688
1926.451 C02
- Issued
- Aug 25, 2023
- Penalty
- Initial $3,349 · Current $335 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation. On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. The scaffold on which work was being completed did not have firm foundation support of base plates and mudsills.
Recent events (2)
- — I (S) $334.9
- — Z (S) $3349
1926.452 J02
- Issued
- Aug 25, 2023
- Penalty
- Initial $3,349 · Current $335 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. The scaffold on which the employee was working was not secured at the bottom by triangular bracing or equivalent.
Recent events (2)
- — I (S) $334.9
- — Z (S) $3349
1926.502 D21
- Issued
- Aug 25, 2023
- Penalty
- Initial $3,349 · Current $335 Reduced
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service. On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. The synthetic rope which was being used as part of a fall protection set up was defective.
Recent events (2)
- — I (S) $334.9
- — Z (S) $3349
1926.1053 B01
- Issued
- Aug 25, 2023
- Penalty
- Initial $3,349 · Current $335 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9m) above the upper landing surface to which the ladder was used to gain access: On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. One of the ladders used to access the roof was not extended three feet above the upper landing surface.
Recent events (2)
- — I (S) $334.9
- — Z (S) $3349
1926.1053 B06
- Issued
- Aug 25, 2023
- Penalty
- Initial $3,349 · Current $335 Reduced
General-duty citation text
29 CFR 1926.1053(b)(6):Unsecured ladder(s) were used on surfaces that were not stable and level. On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. The ladder used to support the fabricated portion of the scaffold was an unsecured A-frame ladder on a n approximately 5/12 roof.
Recent events (2)
- — I (S) $334.9
- — Z (S) $3349
1926.1053 B09
- Issued
- Aug 25, 2023
- Penalty
- Initial $3,349 · Current $335 Reduced
General-duty citation text
29 CFR 1926.1053(b)(9):The area around the top and bottom of ladders was not kept clear On or about 12 April 2023, one employee of CM Exteriors LLC was observed working on a scaffold to put up siding on a residential home located at Lot 100 Amberleigh Manor Drive Wentzville, MO. The area around the top of the extension ladder at the front of the house was not kept clear of debris. The area around the bottom of the access ladder at the rear of the house was surrounded by debris.
Recent events (2)
- — I (S) $334.9
- — Z (S) $3349
More inspections at CM Exteriors LLC
View CM Exteriors LLC's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346640824.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.