Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ULTIUM CELLS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ULTIUM CELLS LLC in 7400 TOD AVENUE SOUTHWEST, WARREN, OH 44481 (NAICS 335912). OSHA activity number 346653751.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ultium Cells LLC — free Get an email when a new federal OSHA severe-injury report for Ultium Cells LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ULTIUM CELLS LLC
Site address
7400 TOD AVENUE SOUTHWEST
City
WARREN
State
OH
ZIP
44481
Mailing
7400 TOD AVENUE SOUTHWEST, WARREN, OH 44481
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335912
Employees
1200
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 80 exposed
Issued
Oct 2, 2023
Abate by
Nov 20, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a) On or about April 24, 2023, where employees worked with and around machinery including, but not limited to Roll Presses, Stocker Units, and Notching and Dryer Machines, the employer did not ensure that periodic inspections  of energy control procedures were conducted.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.147 C07 I A

Deleted Serious Gravity 10 3 instances 80 exposed
Issued
Oct 2, 2023
Abate by
Nov 20, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:   a) On or about April 24, 2023, in the 300 Area Electrode/Assembly, employees conducting maintenance, adjustments and cleaning of the "Roll Press" machines were exposed to in- coming nip points due to the unexpected start of these machines; the employer did not ensure to provide adequate training or, ensure employees understood, the purpose and function of the "HMI pendant(s)" and "SCS pendant(s)", within the energy control program.  b) On or about April 24, 2023, in the 300 Area Electrode/Assembly, employees conducting maintenance, adjustments and cleaning of the "Stocker unit" machines were exposed to struck by hazards due to the unexpected start of these machines; the employer did not ensure to provide adequate training or, ensure employees understood, the purpose and function of the "HMI pendant(s)" and "SCS pendant(s)", within the energy control program.  c) On or about April 24, 2023, in the 300 Area Electrode/Assembly, employees conducting maintenance, adjustments and cleaning of the "Notching and Dryer" machines were exposed to in- coming nip points and struck by hazards due to the unexpected start of these machines; the employer did not ensure to provide adequate training or, ensure employees understood, the purpose and function of the "HMI pendant(s)" and "SCS pendant(s)", within the energy control program.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 2, 2023
Abate by
Aug 30, 2024
Penalty
Initial $11,162 · Current $16,131
Section 5(a)(1) of the Occupational Safety and Health Act:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause serious physical harm to employees in that the interlock system on the Cathode Roll Rewinder in the 300 Area Electrode/Assembly (H-15) was not functioning properly such that employees could be exposed to the infeed rollers.     On or about April 24, 2023, in the 300 Area Electrode/Assembly, H-15, an employee removing a bobbin of scrap from the Cathode Roll Rewinder was exposed to rotating parts from the infeed rollers; the employer did not ensure the interlock on the guard was working to protect the operator and other employees in the machine area from the hazards created by the infeed rollers.  Abatement:  Among other methods, one feasible and acceptable means of abatement would be to implement a system to verify the interlock is functioning correctly.
Recent events (3)
  • — F (S) $16131
  • — C (S) $11162
  • — Z (S) $11162

View Ultium Cells LLC's full OSHA safety record →