Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATL PRO FRAMING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ATL PRO FRAMING LLC in 3515 HALFMOON CT, CUMMING, GA 30041 (NAICS 238130). OSHA activity number 346674039.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ATL PRO Framing LLC — free Get an email when a new federal OSHA severe-injury report for ATL PRO Framing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ATL PRO FRAMING LLC
Site address
3515 HALFMOON CT
City
CUMMING
State
GA
ZIP
30041
Mailing
4414 HICKORY WOOD LANE, DORAVILLE, GA 30360
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2023
Penalty
Initial $2,679 · Current $2,679
29 CFR  1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) New residential construction located at 3515 Halfmoon Ct, Cumming, GA 30041, Roof: On or about 05/03/2023, and at times prior, the employer exposed employees to struck-by hazards while operating pneumatic framing nail guns, in that protective eyewear was not provided to employees operating these tools at 130 PSI. Employees were exposed to plastic and metal collated fragments and fasteners from each tool.
Recent events (1)
  • — Z (S) $2679

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2023
Penalty
Initial $2,679 · Current $2,679
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  a) New residential construction located at 3515 Halfmoon Ct, Cumming, GA 30041, Roof: On or about 05/03/2023, the employer exposed employees to fall hazards of approximately 16-feet, 3-inches to the lower ground level, in that a fall protection system was not provided to employees engaged in framing activities.
Recent events (1)
  • — Z (S) $2679

1926.1053 B01

Serious Gravity 1 1 instance 4 exposed
Issued
May 30, 2023
Penalty
Initial $2,009 · Current $2,009
29 CFR  1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a) New residential construction Located at 3515 Halfmoon Ct, Cumming, GA 30041, Backside of structure: On or about 05/03/2023, the employer exposed employees to fall hazards at approximately 10-feet, in that the ladder used to access the second floor of the structure was not extended at least 3 feet above the upper landing surface.
Recent events (1)
  • — Z (S) $2009

View ATL PRO Framing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346674039.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.