Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANOR TOOL AND MANUFACTURING CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MANOR TOOL AND MANUFACTURING CO. in 9200 IVANHOE STREET, SCHILLER PARK, IL 60176 (NAICS 332119). OSHA activity number 346713381.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manor Tool and Manufacturing CO. — free Get an email when a new federal OSHA severe-injury report for Manor Tool and Manufacturing CO. is published. One employer, no account, unsubscribe in one click.
Site address
9200 IVANHOE STREET
City
SCHILLER PARK
State
IL
ZIP
60176
Mailing
9200 IVANHOE STREET, SCHILLER PARK, IL 60176
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332119
Employees
55
Ownership type
A

4 citations on file for this inspection.

1910.147 F03 II D

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 9, 2023
Abate by
Aug 28, 2023
Penalty
Initial $10,938 · Current $11,250
29 CFR  1910.147(f)(3)(ii)(D):  Each authorized employee did not affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained.   a) On or about February 27, 2023,  employees did not affix their personal lockout or tagout devices to a group lock out device on the main electrical shut off that powered Egan Presspartner Straightener 237B prior to maintenance being performed.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $11250
  • — C (S) $10938
  • — Z (S) $10938

1910.147 D

Serious Gravity 10 3 instances 2 exposed
Issued
Aug 9, 2023
Abate by
Aug 28, 2023
Penalty
Initial $125,007 · Current $11,250 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) On  or about February 27, 2023, employees were exposed to machine hazards associated with moving parts such as steel rollers when servicing and polishing the rollers on the Egan Presspartner Straightener 237B.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy ([d)(5)], and verification of isolation [(d)(5)] were not implemented to protect employees from machine servicing hazards.  b) On February 28, 2023, company employee was exposed to  machine hazards associated with moving parts such as steel rollers when servicing and polishing the rollers on the Egan Presspartner Straightener 237B.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy ([d)(5)], and verification of isolation [(d)(5)] were not implemented to protect employees from machine servicing hazards.  c)  On or about February 28, 2023, company employee was exposed to  machine hazards associated with moving parts such as steel rollers when servicing and polishing the rollers on the Egan Presspartner Straightener 237B.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy ([d)(5)], and verification of isolation [(d)(5)] were not implemented to protect employees from machine servicing hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $11250
  • — C (W) $125007
  • — Z (W) $125007

1910.147 D

Serious Gravity 10 3 instances 2 exposed
Issued
Aug 9, 2023
Abate by
Aug 28, 2023
Penalty
Initial $11,250 · Current $11,250
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) On  or about February 27, 2023, employees were exposed to machine hazards associated with moving parts such as steel rollers when servicing and polishing the rollers on the Egan Presspartner Straightener 237B.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy ([d)(5)], and verification of isolation [(d)(5)] were not implemented to protect employees from machine servicing hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — C (S) $11250
  • — F (S) $11250
  • — Z (S) $11250

1910.147 D

Serious Gravity 10 3 instances 2 exposed
Issued
Aug 9, 2023
Abate by
Aug 28, 2023
Penalty
Initial $11,250 · Current $11,250
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) On February 28, 2023, company employee was exposed to  machine hazards associated with moving parts such as steel rollers when servicing and polishing the rollers on the Egan Presspartner Straightener 237B.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy ([d)(5)], and verification of isolation [(d)(5)] were not implemented to protect employees from machine servicing hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — C (S) $11250
  • — F (S) $11250
  • — Z (S) $11250

View Manor Tool and Manufacturing CO.'s full OSHA safety record →