GALION, OH —
OSHA Inspection: HP INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HP INC. in 1371 SR 598, GALION, OH 44833 (NAICS 325992). OSHA activity number 346719651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HP INC.
- Site address
- 1371 SR 598
- City
- GALION
- State
- OH
- ZIP
- 44833
- Mailing
- 1501 PAGE MILL ROAD., PALO ALTO, CA 94304
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325992
- Employees
- 100
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Aug 29, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $15,625 · Current $10,500 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) HP Inc, on or about May 17, 2023, at the address of 1371598 Galion, OH; The employer did not ensure that energy control procedures were implemented prior to technicians opening protective covers to perform servicing on the HP Indigo W6800p digital press. Employees tasked with servicing an energized Blanket Cleaning System (BCS) on the HP Indigo W6800p digital press without the benefit of energy isolation were exposed to hazards such as but not limited to 400v electrical, 75PSI pneumatics, and pinch points, in that the employers established energy control procedures were not utilized before the employee began the aforementioned task.
Recent events (2)
- — I (S) $10500
- — Z (S) $15625
More inspections at HP INC.
View HP INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325992)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346719651.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.