SHEBOYGAN, WI —
OSHA Inspection: HYGIENIC FABRICS AND FILTERS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HYGIENIC FABRICS AND FILTERS, INC. in 527 N 13TH ST, SHEBOYGAN, WI 53081 (NAICS 314999). OSHA activity number 346723992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HYGIENIC FABRICS AND FILTERS, INC.
- Site address
- 527 N 13TH ST
- City
- SHEBOYGAN
- State
- WI
- ZIP
- 53081
- Mailing
- 527 N 13TH ST, SHEBOYGAN, WI 53081
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314999
- Employees
- 14
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Aug 2, 2023
- Abate by
- Aug 30, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about May 24, 2023, with regard to an establishment located at 527 N 13th Street, Sheboygan, WI 53081, the employer did not ensure that a periodic inspection of it's energy control procedures had been completed on an annual basis to ensure compliance with the standard requirements.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.147 C07 I A
- Issued
- Aug 2, 2023
- Abate by
- Aug 30, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A):Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. On or about April 25, 2023, with regard to an establishment located at 527 N 13th Street, Sheboygan, WI 53081, the employer did not provide Authorized training to employees who were expected to perform service and maintenance tasks, such as clearing jams from the Rosenthal Sheeters.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Aug 2, 2023
- Abate by
- Aug 30, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: On or about May 24, 2023, with regard to an establishment located at 527 N 13th Street, Sheboygan, WI 53081, employees were exposed to machine hazards associated with moving parts during the unjamming of fabric from the Rosenthal Sheeter, Model #WA-S-6-H1UBEVA24, Serial #80243. The employer did not implement energy control application steps as the machine was not shut down or turned off to perform the servicing work per [1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.212 A03 II
- Issued
- Aug 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii):The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. On or about May 24, 2023, with regard to an establishment located at 527 N 13th Street, Sheboygan, WI 53081, the employer did not ensure that employees were protected from machine hazards when the guard on the outfeed side of the Rosenthal Sheeter, Model #WA-S-6-H1UBEVA24, Serial #80243 did not prevent access to the internal cutting blades.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Hygienic Fabrics and Filters, INC.
View Hygienic Fabrics and Filters, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 314999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346723992.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.