Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADAME PALLETS LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ADAME PALLETS LLC in 2117 N. STOUGHTON ROAD, MADISON, WI 53704 (NAICS 321920). OSHA activity number 346743172.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adame Pallets LLC — free Get an email when a new federal OSHA severe-injury report for Adame Pallets LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ADAME PALLETS LLC
Site address
2117 N. STOUGHTON ROAD
City
MADISON
State
WI
ZIP
53704
Mailing
2117 N. STOUGHTON ROAD, MADISON, WI 53704
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
6
Ownership type
A

7 citations on file for this inspection.

1910.95 C01

Repeat Gravity 5 1 instance 6 exposed
Issued
Sep 12, 2023
Abate by
Oct 11, 2023
Penalty
Initial $7,367 · Current $4,868 Reduced

Hazardous substances 81108111

29 CFR 1910.95(c)(1):  The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  On or about June 07, 2023, employees dismantling and building wood pallets were exposed to noise levels exceeding 90 dBA, on 90 dB threshold, and a continuing, effective hearing conservation program was not maintained in that an audiometric testing program was not maintained.  a.  On June 07, 2023, an employee operating a horizontal band saw,  a hammer and a pneumatic nail gun and was exposed to an 8-hour time-weighted average sound level of 96.57 dBA.  Employee was sampled for 270 minutes, the remaining 90 minutes was calculated as 0 (zero) exposure time.     b.  On June 07, 2023, an employee using a pneumatic nail gun was exposed to an 8-hour time-weighted average sound level of 93.74 dBA.  Employee was sampled for sampled for 471 minutes, the remaining 9 minutes was calculated as 0 (zero) exposure time.  Adame Pallets LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.95(c)(1), which was contained in OSHA inspection number 1301659, citation number 1, item number 1 and was affirmed as a final order on July 24, 2018, with respect to a workplace located at 2117 North Stoughton Road in Madison, WI 53704.
Recent events (2)
  • — I (R) $4868
  • — Z (R) $7367

1910.212 A03 II

Repeat Gravity 10 1 instance 1 exposed
Issued
Sep 12, 2023
Abate by
Jan 19, 2024
Penalty
Initial $10,313 · Current $6,574 Reduced
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:  On or about June 02, 2023, the horizontal band saw operator hands were exposed to the cutting side of the blade when pushing the pallets through the blade.  Adame Pallets LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(3)(ii), which was contained in OSHA inspection number 1301659, citation number 1, item number 3 and was affirmed as a final order on July 24, 2018, with respect to a workplace located at 2117 North Stoughton Road in Madison, WI 53704.
Recent events (2)
  • — I (R) $6574
  • — Z (R) $10313

1910.134 C01

Repeat 1 instance 1 exposed
Issued
Sep 12, 2023
Abate by
Jan 19, 2024
Penalty
Initial $251 · Current $0 Reduced

Hazardous substances 9135W103

29 CFR  1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  On or about June 07, 2023 a written respiratory program was not established for employees required to use a N95 filtering face piece respirator when dismantling wood pallets.  Adame Pallets LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(c)(1), which was contained in OSHA inspection number 1301659, citation number 1, item number 2b and was affirmed as a final order on July 24, 2018, with respect to a workplace located at 2117 North Stoughton Road in Madison, WI 53704.
Recent events (2)
  • — I (R) $0
  • — Z (R) $251

1910.178 L04 III

Repeat 1 instance 2 exposed
Issued
Sep 12, 2023
Abate by
Oct 11, 2023
Penalty
Initial $251 · Current $0 Reduced
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:   On or about June 01, 2023, an employee operated a LP forklift without being evaluated once every 3 years.  Adame Pallets LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.178(l)(1)(i), which was contained in OSHA inspection number 1301659, citation number 2, item number 1 and was affirmed as a final order on July 24, 2018, with respect to a workplace located at 2117 North Stoughton Road in Madison, WI 53704.
Recent events (2)
  • — I (R) $0
  • — Z (R) $251

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Sep 12, 2023
Abate by
Jan 19, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 9135W103

29 CFR  1910.134(e)(1):  The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  On or about June 07, 2023, it was mandatory for employee to wear a N95 filtering facepiece respirator when dismantling  wood pallets and was not provided a respirator medical evaluation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F01

Other-than-serious 1 instance 1 exposed
Issued
Sep 12, 2023
Abate by
Jan 19, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 9135W103

29 CFR  1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  On or about June 07, 2023, it was mandatory for employee to wear a N95 filtering facepiece respirator when dismantling  wood pallets and was not provided a respirator fit test.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 G

Other-than-serious 1 instance 1 exposed
Issued
Sep 12, 2023
Abate by
Jan 19, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 9135W103

29 CFR  1910.134(g):  The employer did not establish and implement procedures for the proper use of respirators, including taking action to ensure continued effective respirator operation throughout the work shift:  On or about June 07, 2023,  an employee was required to use a N95 filtering face piece respirator when dismantling wood pallets and did not have the bottom strap of the N95 filtering face piece respirator in a secure position behind employee's neck.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Adame Pallets LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346743172.