Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DOOSAN UKUDU POWER, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DOOSAN UKUDU POWER, LLC in LOT 5010-1 NEW-NEW-R1, DEDEDO, GU 96912 (NAICS 237130). OSHA activity number 346768666.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Doosan Ukudu Power, LLC — free Get an email when a new federal OSHA severe-injury report for Doosan Ukudu Power, LLC is published. One employer, no account, unsubscribe in one click.
Site address
LOT 5010-1 NEW-NEW-R1
City
DEDEDO
State
GU
ZIP
96912
Mailing
148 ROAD G. APT. C, TAMUNING, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
63
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 10, 2023
Penalty
Initial $3,984 · Current $3,984
29 CFR  1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  Trench Section 9229: No means of egress were provided for employees testing the newly installed LPG pipe. Employees were exposed to fall and entrapment hazards.
Recent events (1)
  • — Z (S) $3984

1926.651 J02

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 10, 2023
Penalty
Initial $3,984 · Current $3,984
29 CFR  1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection by placing and keeping such materials or equipment at least 2 feet from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary was not provided.  Trench Section SINAJANA C2-2: The spoil pile was located directly on the edge of the trench where employees were working inside the trench to check the joints of installed pipes. Employees were exposed to struck-by and engulfment hazards.
Recent events (1)
  • — Z (S) $3984

View Doosan Ukudu Power, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346768666.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.