SALINA, KS —
OSHA Inspection: SFC GLOBAL SUPPLY CHAIN, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SFC GLOBAL SUPPLY CHAIN, INC. in 3019 SCANLAN AVE, SALINA, KS 67401 (NAICS 311412). OSHA activity number 346770084.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SFC GLOBAL SUPPLY CHAIN, INC.
- Site address
- 3019 SCANLAN AVE
- City
- SALINA
- State
- KS
- ZIP
- 67401
- Mailing
- 1701 W. SHILLING RD., SALINA, KS 67401
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311412
- Employees
- 1500
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 E03 VI
- Issued
- Nov 21, 2023
- Abate by
- Jan 10, 2024
- Penalty
- Initial $11,162 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(vi): The process hazard analysis did not address human factors: At the facility located at 3019 Scanlon Avenue, Salina, Kansas, the employer failed to properly name the Accumulator vessel in room 901 on the CP-2 engine room monitor. The Accumulator was named on the computer monitor as +10 F Recirculator. The process hazard analysis did not address mislabeling of ammonia vessels that can lead to human errors during the operation of the ammonia refrigeration system. Employees engaged in operating, inspecting, testing, and maintaining activities in the ammonia refrigeration system at the facility were exposed to catastrophic release of ammonia which results in asphyxiation, explosion and flash fire leading to death and injury.
Recent events (2)
- — I (S) $0
- — Z (S) $11162
1910.119 F01 III E
- Issued
- Nov 21, 2023
- Abate by
- Jan 10, 2024
- Penalty
- Initial $15,625 · Current $15,625
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(E): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and did not address any special or unique hazards: At the facility located a 3019 Scanlan Avenue, Salina, Kansas, the employer failed to include in the standard operating procedures for the Evaporative Condensers the cable locked valves as a critical safety valve. Employees and contractor employees using the Evaporative Condenser standard operating procedures for the ammonia refrigeration system were not provided with a description of the safety critical valves being included in the procedure. Employees engaged in operating, inspecting, testing, and maintaining activities in the ammonia refrigeration system at the facility were exposed to catastrophic release of ammonia which results in asphyxiation, explosion and flash fire leading to death and injury.
Recent events (2)
- — I (O) $15625
- — Z (S) $15625
1910.119 L01
- Issued
- Nov 21, 2023
- Abate by
- Jan 10, 2024
- Penalty
- Initial $15,625 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(l)(1):29 CFR 1910.119(l)(1): The employer did not establish and implement written procedures to manage changes to process chemicals, technology, equipment, and procedures; and, changes to facilities that affect a covered process: At the facility located at 3019 Scanlan Avenue, Salina, Kansas, the employer had not implemented the management of change program to address changes to the ammonia refrigeration system that can result in hazards associated with operating ammonia refrigeration equipment such as, but not limited to the following: (a) The employer did not have any documentation for the perimeter fencing being placed around the outside ammonia refrigeration equipment. (b) The employer did not have any documentation for the electronic badging system being installed for the ammonia refrigeration equipment. (c) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9A-N) valve HV04. (d) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9A-N) valve HV05. (e) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9B-N) valve HV04. (f) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9B-N) valve HV05. (g) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9A-S) valve HV04. (h) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9A-S) valve HV05. (i) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9B-S) valve HV04. (j) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9B-S) valve HV05. (k) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9C-S) valve HV04. (l) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9C-S) valve HV05. (m) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9D-S) valve HV04. (n) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9D-S) valve HV05. (o) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9E-S) valve HV04. (p) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9E-S) valve HV05. (q) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9F-S) valve HV04. (r) The employer did not have any documentation for the cable used to lock open Evaporative Condenser (EC9F-S) valve HV05. Employees engaged in operating, inspecting, testing, and maintaining activities in the ammonia refrigeration system at the facility were exposed to catastrophic release of ammonia which results in asphyxiation, explosion and flash fire leading to death and injury.
Recent events (2)
- — I (O) $0
- — Z (S) $15625
1910.119 H02 I
- Issued
- Nov 21, 2023
- Abate by
- Jan 10, 2024
- Penalty
- Initial $15,625 · Current $15,625
General-duty citation text
29 CFR 1910.119(h)(2)(i): The employer, when selecting a contractor, did not obtain and evaluate information regarding the contract employer's safety performance and program: At the establishment located at 3019 Scanlan Avenue, Salina, Kansas, the employer failed to obtain the safety and health programs of the ammonia contactor that delivers and participates in the unloading of highly hazardous chemicals into the ammonia refrigeration system. The driver of the ammonia tanker truck used their company's hoses and equipment to transfer the highly hazardous chemical. Employees engaged in operating, inspecting, testing, and maintaining activities in the ammonia refrigeration system at the facility were exposed to catastrophic release of ammonia which results in asphyxiation, explosion and flash fire leading to death and injury.
Recent events (2)
- — I (O) $15625
- — Z (S) $15625
1910.119 J05
- Issued
- Nov 21, 2023
- Abate by
- Jan 10, 2024
- Penalty
- Initial $11,162 · Current $11,162
General-duty citation text
29 CFR 1910.119(j)(5): Equipment deficiencies. The employer shall correct deficiencies in equipment that are outside acceptable limits before further use or in a safe and timely manner when necessary means are taken to assure safe operation. The employer failed to repair an ammonia pipe hanger support above the Accumulator in room 901 located at 3910 Scanlon Avenue, Salina, Kansas. One side of the ammonia pipe hanger support was no longer connected to the mounting plate. Employees engaged in operating, inspecting, testing, and maintaining activities in the ammonia refrigeration system at the facility were exposed to catastrophic release of ammonia which results in asphyxiation, explosion and flash fire leading to death and injury.
Recent events (2)
- — I (O) $11162
- — Z (S) $11162
1910.303 B02
- Issued
- Nov 21, 2023
- Penalty
- Initial $11,162 · Current $11,162
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listed or labeling: Employees working in the engine room were exposed to electrical burn hazards located at 1701 Shilling Road, Salina Kansas due to receptacle boxes being wired with a flexible cord and not securely affixed to any surface. A receptacle box along the south wall of the engine room was being used as an extension cord for electrical equipment.
Recent events (2)
- — I (O) $11162
- — Z (S) $11162
1910.303 G02
- Issued
- Nov 21, 2023
- Abate by
- Jan 10, 2024
- Penalty
- Initial $11,162 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures: (a) Employee(s) working in room 901 next to the Accumulator located at 1701 Shilling Road, Salina, Kansas were exposed to electrical burn hazards due to junction box cover not guarding against exposure to energized wiring/ electrical components inside the box. (b) Employee(s) working in the engine room (south entrance door) located at 1701 Shilling Road, Salina, Kansas were exposed to electrical burn hazards due to energized Romex flexible wiring approximately 2 inches in length not being enclosed in conduit. The energized section of wiring was approximately 92 inches above ground. (c) Employee(s) working in the engine room (column post left of locker room) located at 1701 Shilling Road, Salina, Kansas were exposed to electrical burn hazards due to energized Romex flexible wiring approximately 1 inch in length not being enclosed in conduit. The energized section of wiring was approximately 92 inches above ground.
Recent events (2)
- — I (O) $0
- — Z (S) $11162
1910.305 G01 IV A
- Issued
- Nov 21, 2023
- Penalty
- Initial $11,162 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for fixed wiring of a structure: Along the south wall of the ammonia refrigeration engine room an extension cord was placed behind column posts to power a WIFI repeater located at 1701 Shilling Road, Salina Kansas. Employees were exposed to electrical burn hazards due to the extension cord being used as a substitute for fixed wiring.
Recent events (2)
- — I (O) $0
- — Z (S) $11162
More inspections at SFC Global Supply Chain, INC.
View SFC Global Supply Chain, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311412)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346770084.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.