FORT WORTH, TX —
OSHA Inspection: R2 FABRICATION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R2 FABRICATION, LLC in 804 S. BLUE MOUND ROAD, FORT WORTH, TX 76131 (NAICS 332312). OSHA activity number 346778376.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R2 FABRICATION, LLC
- Site address
- 804 S. BLUE MOUND ROAD
- City
- FORT WORTH
- State
- TX
- ZIP
- 76131
- Mailing
- 804 S. BLUE MOUND ROAD, FORT WORTH, TX 76131
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 40
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.212 A03 IV F
- Issued
- Jul 10, 2023
- Penalty
- Initial $5,313 · Current $3,188 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(iv)(f):The point of operation of power saws whose operation exposed an employee to injury were not guarded. On or about June 20, 2023, and times prior thereto, in the cutting shop area, employees operated a DeWalt chop saw with a missing guard exposing employees to cuts and abrasion hazards.
Recent events (2)
- — I (S) $3187.8
- — Z (S) $5313
1910.304 F01 VIII
- Issued
- Jul 10, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $4,687 · Current $2,812 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(viii): The employer shall ensure that all circuit breakers used as switches are labelled "SWD". On or about June 20, 2023, and times prior thereto, the employees turn on lights from the electrical panel boxes and circuits were not listed and marked "SWD". a) In the cutting shop area, electrical panel box used to turn on and off lights, b) In the welding shop area, electrical panel box used to turn on and off lights.
Recent events (2)
- — I (S) $2812.2
- — Z (S) $4687
1910.333 A
- Issued
- Jul 10, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $4,687 · Current $2,812 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized. On or about June 20, 2023, and times prior thereto, where the duct line main switch panel was not locked out and/or tagout prior to the maintenance employee(s) performing maintenance on the duct line machine, exposing the employee caught-in hazards.
Recent events (2)
- — I (S) $2812.2
- — Z (S) $4687
1910.333 B01
- Issued
- Jul 10, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(1): The employer did not ensure that exposed deenergized parts were locked out and tagged in accordance with paragraph (b) and treated them as energized parts. On or about June 20, 2023, and times prior thereto, where employees began working on a machine that was deenergized and was not locked out from inadvertent re-energization exposing the employees to caught-in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 B02
- Issued
- Jul 10, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): On or about June 20, 2023, and times prior thereto, employee working on the duct line machine did not lockout and/or tagout the main switch panel to prevent re-energization and exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01
- Issued
- Jul 10, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $877 · Current $526 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed. On or about June 20, 2023, and times prior thereto, knockouts were missing from energized electrical panel boxes exposing employees to electrical shock hazards. a) In the welding shop, the power box that energize the Scotchman Iron Work machine was missing 2 knockouts, b) The TDF machine power box was missing a knockout.
Recent events (2)
- — I (O) $526.2
- — Z (O) $877
1910.253 B02 IV
- Issued
- Jul 10, 2023
- Penalty
- Initial $746 · Current $448 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use. On or about June 20, 2023, and times prior thereto, on the southside of the welding shop area, an unused oxygen cylinder stored without the protective cap exposed employees to struck-by hazards in the event the bottle was knocked over.
Recent events (2)
- — I (O) $447.6
- — Z (O) $746
More inspections at R2 Fabrication, LLC
View R2 Fabrication, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346778376.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.