Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DELOS REYES PALM SPRINGS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DELOS REYES PALM SPRINGS in 1277 SOUTH PALM CANYON DRIVE, PALM SPRINGS, CA 92264 (NAICS 721110). OSHA activity number 346824675.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Delos Reyes Palm Springs — free Get an email when a new federal OSHA severe-injury report for Delos Reyes Palm Springs is published. One employer, no account, unsubscribe in one click.
Site address
1277 SOUTH PALM CANYON DRIVE
City
PALM SPRINGS
State
CA
ZIP
92264
Mailing
1277 SOUTH PALM CANYON DRIVE, PALM SPRINGS, CA 92264
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
6
Ownership type
A

8 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 28, 2023
Abate by
Aug 9, 2023
Penalty
Initial $2,679 · Current $1,473 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   On and/or before July 11, 2023, the employer used extension cords and surge protectors to power various pieces of equipment.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  In the following locations: a)Laundry room two extension cords were spliced together and one end terminated in an outlet box.  The outlet box was powering an Amana air conditioner unit. b) Lobby storage room had an extension cord plugged into a surge protector to power a microwave and coffee maker.
Recent events (2)
  • — I (S) $1473.45
  • — Z (S) $2679

1910.303 B08 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 28, 2023
Abate by
Aug 9, 2023
Penalty
Initial $2,679 · Current $1,473 Reduced
29 CFR  1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was mounted.  Post outside the laundry room: On and/or before July 11, 2023, the employer did not secure a junction box that had exposed wiring.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (2)
  • — I (S) $1473.45
  • — Z (S) $2679

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 28, 2023
Abate by
Aug 9, 2023
Penalty
Initial $2,679 · Current $1,473 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   Panel across from the electrical room: On and/or before July 11, 2023, the employer did not ensure two openings in the electrical panel were effectively closed.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (2)
  • — I (S) $1473.45
  • — Z (S) $2679

1910.305 B02 I

Serious Gravity 5 3 instances 3 exposed
Issued
Jul 28, 2023
Abate by
Aug 9, 2023
Penalty
Initial $2,679 · Current $1,473 Reduced
29 CFR  1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On and/or before July 11, 2023, the employer did not cover a four-outlet box with a faceplate, and two junction boxes were missing a cover exposing the inner wires.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  In the following locations: a) Pool area on the pump room wall b) Under the stairs next to the electrical room c) Laundry room next to washer
Recent events (2)
  • — I (S) $1473.45
  • — Z (S) $2679

1910.305 G01 IV A

Serious Gravity 5 3 instances 3 exposed
Issued
Jul 28, 2023
Abate by
Aug 9, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   On and/or before July 11, 2023, the employer used extension cords and surge protectors to power various pieces of equipment.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  In the following locations: a) Laundry room two extension cords were spliced together and one end terminated in an outlet box.  The outlet box was powering an Amana air conditioner unit. b) Laundry room two ends of an extension cord were cut and tied into the hot water heater circulation pump system. c) Lobby storage room had an extension cord plugged into a surge protector to power a microwave and coffee maker.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D02

Other-than-serious 1 instance 3 exposed
Issued
Jul 28, 2023
Abate by
Oct 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  On and/or before July 11, 2023, the employer did not have a written personal protective equipment (PPE) assessment.  This condition potentially exposed employees to injuries to the eyes, face, and hands.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 2 exposed
Issued
Jul 28, 2023
Abate by
Aug 23, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Lobby: On and/or before July 11, 2023, the employer did not conduct monthly fire extinguisher inspections.  This condition potentially exposed employee(s) to fire hazard(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 2 instances 3 exposed
Issued
Jul 28, 2023
Abate by
Aug 23, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:   On and/or before July 11, 2023, the employer did not ensure each circuit breaker was legibly marked to indicate its purpose in the electrical panels.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  In the following locations: a) Laundry room b) Wall across from the electrical room
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Delos Reyes Palm Springs's full OSHA safety record →