PALM SPRINGS, CA —
OSHA Inspection: DELOS REYES PALM SPRINGS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELOS REYES PALM SPRINGS in 1277 SOUTH PALM CANYON DRIVE, PALM SPRINGS, CA 92264 (NAICS 721110). OSHA activity number 346824675.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELOS REYES PALM SPRINGS
- Site address
- 1277 SOUTH PALM CANYON DRIVE
- City
- PALM SPRINGS
- State
- CA
- ZIP
- 92264
- Mailing
- 1277 SOUTH PALM CANYON DRIVE, PALM SPRINGS, CA 92264
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.303 B02
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $2,679 · Current $1,473 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On and/or before July 11, 2023, the employer used extension cords and surge protectors to power various pieces of equipment. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following locations: a)Laundry room two extension cords were spliced together and one end terminated in an outlet box. The outlet box was powering an Amana air conditioner unit. b) Lobby storage room had an extension cord plugged into a surge protector to power a microwave and coffee maker.
Recent events (2)
- — I (S) $1473.45
- — Z (S) $2679
1910.303 B08 I
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $2,679 · Current $1,473 Reduced
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was mounted. Post outside the laundry room: On and/or before July 11, 2023, the employer did not secure a junction box that had exposed wiring. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (2)
- — I (S) $1473.45
- — Z (S) $2679
1910.305 B01 II
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $2,679 · Current $1,473 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Panel across from the electrical room: On and/or before July 11, 2023, the employer did not ensure two openings in the electrical panel were effectively closed. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (2)
- — I (S) $1473.45
- — Z (S) $2679
1910.305 B02 I
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $2,679 · Current $1,473 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On and/or before July 11, 2023, the employer did not cover a four-outlet box with a faceplate, and two junction boxes were missing a cover exposing the inner wires. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following locations: a) Pool area on the pump room wall b) Under the stairs next to the electrical room c) Laundry room next to washer
Recent events (2)
- — I (S) $1473.45
- — Z (S) $2679
1910.305 G01 IV A
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On and/or before July 11, 2023, the employer used extension cords and surge protectors to power various pieces of equipment. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following locations: a) Laundry room two extension cords were spliced together and one end terminated in an outlet box. The outlet box was powering an Amana air conditioner unit. b) Laundry room two ends of an extension cord were cut and tied into the hot water heater circulation pump system. c) Lobby storage room had an extension cord plugged into a surge protector to power a microwave and coffee maker.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Jul 28, 2023
- Abate by
- Oct 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): On and/or before July 11, 2023, the employer did not have a written personal protective equipment (PPE) assessment. This condition potentially exposed employees to injuries to the eyes, face, and hands.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Jul 28, 2023
- Abate by
- Aug 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Lobby: On and/or before July 11, 2023, the employer did not conduct monthly fire extinguisher inspections. This condition potentially exposed employee(s) to fire hazard(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 F02
- Issued
- Jul 28, 2023
- Abate by
- Aug 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On and/or before July 11, 2023, the employer did not ensure each circuit breaker was legibly marked to indicate its purpose in the electrical panels. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following locations: a) Laundry room b) Wall across from the electrical room
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Delos Reyes Palm Springs
View Delos Reyes Palm Springs's full OSHA safety record →
More inspections in this industry (NAICS 721110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346824675.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.