SPOONER, WI —
OSHA Inspection: ADVANCED LASER MACHINING, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of ADVANCED LASER MACHINING, INC. in 1100 ROUNDHOUSE ROAD, SPOONER, WI 54801 (NAICS 333517). OSHA activity number 346830110.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED LASER MACHINING, INC.
- Site address
- 1100 ROUNDHOUSE ROAD
- City
- SPOONER
- State
- WI
- ZIP
- 54801
- Mailing
- 600 CASHMAN DR, CHIPPEWA FALLS, WI 54729
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333517
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C02 II
- Issued
- Sep 29, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(2)(ii): The employer's tagout energy control program procedures did not successfully comply with 29 CFR 1910.147(c)(3) and no lockout was provided for employee protection: (a) West production area; When service and maintenance tasks were performed on the Mazak STX510 Laser, tagout was used in lieu of lockout on energy isolation devices that were capable of being locked out.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 II
- Issued
- Sep 29, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) Throughout the facility; Periodic inspections performed on equipment in which equipment-specific energy control procedures were utilized, were not documented by the employer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Advanced Laser Machining, INC.
View Advanced Laser Machining, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333517)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346830110.