OSHA Inspection: DOGGETT FREIGHTLINER OF SOUTH TEXAS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DOGGETT FREIGHTLINER OF SOUTH TEXAS in 1367 N. HORIZON BLVD. BUILDING A, EL PASO, TX 79928 (NAICS 441310). OSHA activity number 346855034.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Doggett Freightliner of South Texas — free Get an email when a new federal OSHA severe-injury report for Doggett Freightliner of South Texas is published. One employer, no account, unsubscribe in one click.
Site address
1367 N. HORIZON BLVD. BUILDING A
City
EL PASO
State
TX
ZIP
79928
Mailing
1367 N. HORIZON BLVD., EL PASO, TX 79928
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
85
Ownership type
A

6 citations on file for this inspection.

1910.303 B01 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 14, 2023
Abate by
Oct 10, 2023
Penalty
Initial $13,394 · Current $7,000 Reduced
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:  On or about July 24, 2023, and at times prior thereto, in Building A (Warehouse Department), an orange (16 AWG) extension cord used to supply power to a Porta cool Jetstream 36# Variable Speed PACJ2601A1 120VAC/60HZ 9.3 APS Serial #531849, was damaged and had insulation cuts with exposed inner conductors. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $13394

1904.32 A01

Other-than-serious 2 instances 85 exposed
Issued
Sep 14, 2023
Abate by
Oct 10, 2023
Penalty
Initial $2,232 · Current $2,000 Reduced
29 CFR 1904.32(a)(1): Basic requirement. At the end of each calendar year, you must review the OSHA 300 Log to verify that the entries are complete and accurate, and correct any deficiencies identified.  On or about July 24, 2023, the information provided on the OSHA 300 Logs and the OSHA 300 A Summaries for Work Related Injury and Illnesses was not reviewed for accuracy. The total recordable cases do not equal the total of injuries and illnesses in the following instances:  1) OSHA 300 Log /300A 2021  2) OSHA 300 Log/300A 2020
Recent events (2)
  • — I (O) $2000
  • — Z (O) $2232

1910.303 C03 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 14, 2023
Abate by
Oct 10, 2023
Penalty
Initial $1,253 · Current $1,000 Reduced
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices were not first spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:  On or about July 24, 2023, and at times prior thereto, in Building A (Warehouse department), the splices on a Porta cool Jetstream 36# Variable Speed PACJ2601A1 120VAC/60HZ 9.3 APS Serial #531849 were not spliced or joined together by brazing, welding, or soldering with a fusible metal or alloy. This condition exposed employees to electrical shock and fire hazards.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1253

1910.305 A02 X

Other-than-serious 1 instance 2 exposed
Issued
Sep 14, 2023
Abate by
Oct 10, 2023
Penalty
Initial $1,253 · Current $1,000 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:   On or about July 24, 2023, and at times prior thereto, in Building A (Warehouse) a (16 AWG) orange extension cord was run through the top of a cabinet door and was being pinched. The extension cord was being used to power a Porta cool Jetstream 36# Variable Speed PACJ2601A1 120VAC/60HZ 9.3 APS Serial #531849. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1253

1910.305 J02 IV

Other-than-serious 1 instance 2 exposed
Issued
Sep 14, 2023
Abate by
Oct 10, 2023
Penalty
Initial $1,253 · Current $1,000 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:  On or about July 24, 2023, and at times prior thereto, in Building A(Warehouse), the receptacle next to the sink was not GFCI. This exposed employees to electrical hazards.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1253

1910.334 A02 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 14, 2023
Abate by
Oct 10, 2023
Penalty
Initial $1,253 · Current $1,000 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about July 24, 2023, employees were exposed to electrical hazards when damaged / defective extension cords were used to power equipment in the following instances:  1) Building A (Warehouse) a (16 AWG) orange extension cord was run through the top of a cabinet door and was being pinched and had insulation cuts.   2) Building A (Warehouse department), the splices on the Porta cool Jetstream 36# Variable Speed PACJ2601A1 120VAC/60HZ 9.3 APS Serial #531849, were not spliced or joined together by brazing, welding, or soldering with a fusible metal or alloy.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1253

View Doggett Freightliner of South Texas's full OSHA safety record →