CONCORD, CA —
OSHA Inspection: C2 ALASKA, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of C2 ALASKA, LLC in 410 NORMAN AVE., BUILDING NO. 350, CONCORD, CA 94520 (NAICS 811198). OSHA activity number 346859929.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C2 ALASKA, LLC
- Site address
- 410 NORMAN AVE., BUILDING NO. 350
- City
- CONCORD
- State
- CA
- ZIP
- 94520
- Mailing
- 410 NORMAN AVE., BUILDING NO. 350, CONCORD, CA 94520
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811198
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C05 I
- Issued
- Nov 22, 2023
- Penalty
- Initial $11,385 · Current $6,831 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources. On or about July 25, 2023 and preceding at the Military Ocean Terminal Concord C2 Alaska, LLC operations, employees were not provided with the proper equipment or hardware for isolating, securing or blocking of machines or equipment energy sources. Employees were exposed to electric, hydraulic, and kinetic energy hazards.
Recent events (2)
- — I (S) $6831
- — Z (S) $11385
1910.147 C04 II
- Issued
- Nov 22, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. On or about July 25, 2023 and preceding at the Military Ocean Terminal Concord C2 Alaska, LLC operations, the employer was unable to provide or identify specific procedures for controlling hazardous energy. Employees performing vehicle maintenance and repair did not have specific lock out/tag out procedures to effectively control all hazardous energy sources such as electric, hydraulic, and kinetic energy. Employees were exposed to electric, hydraulic, and kinetic energy hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 IV
- Issued
- Nov 22, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv):The employer did not certify that employee training has been accomplished and is being kept up to date. On or about July 25, 2023 and preceding, the employer did not keep or certify employee safety training on the isolation or control of hazardous energy. Employees were exposed to electric, hydraulic, and kinetic energy hazards that could result in electric shock, burns, or crushing injuries.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 C02
- Issued
- Nov 22, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $8,929 · Current $5,357 Reduced
General-duty citation text
29 CFR 1910.184(c)(2):A sling was shortened with knots or bolts or other makeshift devices. On or about July 25, 2023 a chain sling used to connect a drum handling attachment to the overhead crane in B-Bay was fastened into a loop using a bolt. Employees are exposed to crushing injuries from falling loads.
Recent events (2)
- — I (S) $5357.4
- — Z (S) $8929
1910.184 E01
- Issued
- Nov 22, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(1):Sling identification. The alloy steel chain sling did not have permanently affixed durable identification stating size, grade, rated capacity, and reach. In B-bay, the chain sling used to connect a barrel handling attachment to the south crane was not labeled with an identification tag. Employees were exposed to crushing injuries by not being able to identify its rated capacity.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Nov 22, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2):Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. In B-bay, electrical panel L-2 did not have breakers labeled to identify the equipment they were used for. Employees regularly work in this bay and are exposed burns, smoke inhalation, and other injuries resulting from malfunctioning equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at C2 Alaska, LLC
View C2 Alaska, LLC's full OSHA safety record →
More inspections in this industry (NAICS 811198)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346859929.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.