Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DESERT PRINCESS HOME-OWNERS ASSOCIATION INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DESERT PRINCESS HOME-OWNERS ASSOCIATION INC in 28555 LANDAU BLVD, CATHEDRAL CITY, CA 92234 (NAICS 713910). OSHA activity number 346862709.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Desert Princess Home-Owners Association INC — free Get an email when a new federal OSHA severe-injury report for Desert Princess Home-Owners Association INC is published. One employer, no account, unsubscribe in one click.
Site address
28555 LANDAU BLVD
City
CATHEDRAL CITY
State
CA
ZIP
92234
Mailing
28211 DESERT PRINCESS DR, CATHEDRAL CITY, CA 92234
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713910
Employees
39
Ownership type
A

7 citations on file for this inspection.

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 25, 2023
Abate by
Oct 5, 2023
Penalty
Initial $8,539 · Current $5,123 Reduced
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  Facilities, Bldg. 67177: On and/or before July 26, 2023, employee(s) used compressed air to remove dust from filters, radiators, and tires. Compressed air was measured at over 60 p.s.i. This condition potentially exposed employee(s) to cutaneous or subcutaneous laceration(s)/embolism hazard(s).
Recent events (2)
  • — I (S) $5123
  • — Z (S) $8539

1910.303 B02

Serious Gravity 5 6 instances 3 exposed
Issued
Sep 25, 2023
Abate by
Oct 10, 2023
Penalty
Initial $6,831 · Current $4,099 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On and/or before July 26, 2023, multiple appliances/machines such as the Television, Computer, Refrigerator, KitchenAid Mixer and an Amana Microwave were plugged into a relocatable power tap in which were not used according to listing and labeling instructions. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  In the following locations: a) Main Bar, Television and Computer b) Main Kitchen, KitchenAid Mixer   c) Main Kitchen, Amana Microwave d) Main Kitchen, Turbo Air cold-holding unit e) Facilities Bldg. 67177, Arctic King Fridge f) Gold Course Maintenance Facility, Magic Chef Microwave
Recent events (2)
  • — I (S) $4099
  • — Z (S) $6831

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 25, 2023
Abate by
Oct 5, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  Golf Course Maintenance Facility: On and/or before July 26, 2023, flexible cords and/or cables were used as a source of permanent power for the Magic Chef Microwave. This condition potentially exposed employees to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 25, 2023
Abate by
Oct 5, 2023
Penalty
Initial $6,831 · Current $4,099 Reduced
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  On and/or before July 26, 2023, the employer did not ensure at least 3 feet in front of the electrical panel was clear. The circuit breaker panel had multiple appliances and/or equipment such as Pressurized Cylinder(s), Red Crate, Waring Commercial Belgian Waffle Maker, Cold Holding unit, Fridge, and a Red tool table obstructing the panel. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  In the following location(s): a) Lagos Kitchen, Pressurized Cylinder(s), Red Crate, Waring Commercial Belgian Waffle Maker, Cold Holding b) Facilities Bldg. 67177, Fridge c) Golf course maintenance facility, Red Tool table
Recent events (2)
  • — I (S) $4099
  • — Z (S) $6831

1910.305 B02 I

Serious Gravity 5 4 instances 4 exposed
Issued
Sep 25, 2023
Abate by
Oct 5, 2023
Penalty
Initial $6,831 · Current $4,099 Reduced
29 CFR  1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  On and/or before July 26, 2023, employee(s) were tasked to use multiple appliance/machines such as the computer, coffee machine and the beer cooler for customer service duties. The energized electrical outlet was missing the protective faceplate. Employee(s) were potentially exposed to electrical shock and/or fire hazard(s).  In the following location(s): a) Golf Shop, outlet box near the computer b) Lagos Kitchen, outlet box near the Coffee Machine c) Main Bar, outlet box behind the True refrigerator Beer cooler d) Facilities bldg. 67177, outlet box on the right side of the black storage rack.
Recent events (2)
  • — I (S) $4099
  • — Z (S) $6831

1910.37 A03

Other-than-serious 1 instance 1 exposed
Issued
Sep 25, 2023
Abate by
Oct 5, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  Golf Shop: On and/or before July 26, 2023, employee(s) would pass through the exit door to use the restrooms. Multiple items were stored along the path of the exit route leading to the restroom(s). This condition potentially exposed employee(s) to fire hazard(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 2 instances 2 exposed
Issued
Sep 25, 2023
Abate by
Oct 5, 2023
Penalty
Initial $959 · Current $574 Reduced
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  On and/or before July 26, 2023, multiple fire extinguisher(s) were not mounted to the wall. This condition potentially exposed employee(s) to fire and/or smoke inhalation hazards.  In the following location(s):  a) Golf Shop b) Facilities Bldg. 67177
Recent events (2)
  • — I (O) $574
  • — Z (O) $959

View Desert Princess Home-Owners Association INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346862709.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.