CATHEDRAL CITY, CA —
OSHA Inspection: DESERT PRINCESS HOME-OWNERS ASSOCIATION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DESERT PRINCESS HOME-OWNERS ASSOCIATION INC in 28555 LANDAU BLVD, CATHEDRAL CITY, CA 92234 (NAICS 713910). OSHA activity number 346862709.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DESERT PRINCESS HOME-OWNERS ASSOCIATION INC
- Site address
- 28555 LANDAU BLVD
- City
- CATHEDRAL CITY
- State
- CA
- ZIP
- 92234
- Mailing
- 28211 DESERT PRINCESS DR, CATHEDRAL CITY, CA 92234
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713910
- Employees
- 39
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.242 B
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $8,539 · Current $5,123 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. Facilities, Bldg. 67177: On and/or before July 26, 2023, employee(s) used compressed air to remove dust from filters, radiators, and tires. Compressed air was measured at over 60 p.s.i. This condition potentially exposed employee(s) to cutaneous or subcutaneous laceration(s)/embolism hazard(s).
Recent events (2)
- — I (S) $5123
- — Z (S) $8539
1910.303 B02
- Issued
- Sep 25, 2023
- Abate by
- Oct 10, 2023
- Penalty
- Initial $6,831 · Current $4,099 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On and/or before July 26, 2023, multiple appliances/machines such as the Television, Computer, Refrigerator, KitchenAid Mixer and an Amana Microwave were plugged into a relocatable power tap in which were not used according to listing and labeling instructions. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following locations: a) Main Bar, Television and Computer b) Main Kitchen, KitchenAid Mixer c) Main Kitchen, Amana Microwave d) Main Kitchen, Turbo Air cold-holding unit e) Facilities Bldg. 67177, Arctic King Fridge f) Gold Course Maintenance Facility, Magic Chef Microwave
Recent events (2)
- — I (S) $4099
- — Z (S) $6831
1910.305 G01 IV A
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. Golf Course Maintenance Facility: On and/or before July 26, 2023, flexible cords and/or cables were used as a source of permanent power for the Magic Chef Microwave. This condition potentially exposed employees to electrical shock and/or fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $6,831 · Current $4,099 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On and/or before July 26, 2023, the employer did not ensure at least 3 feet in front of the electrical panel was clear. The circuit breaker panel had multiple appliances and/or equipment such as Pressurized Cylinder(s), Red Crate, Waring Commercial Belgian Waffle Maker, Cold Holding unit, Fridge, and a Red tool table obstructing the panel. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s). In the following location(s): a) Lagos Kitchen, Pressurized Cylinder(s), Red Crate, Waring Commercial Belgian Waffle Maker, Cold Holding b) Facilities Bldg. 67177, Fridge c) Golf course maintenance facility, Red Tool table
Recent events (2)
- — I (S) $4099
- — Z (S) $6831
1910.305 B02 I
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $6,831 · Current $4,099 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On and/or before July 26, 2023, employee(s) were tasked to use multiple appliance/machines such as the computer, coffee machine and the beer cooler for customer service duties. The energized electrical outlet was missing the protective faceplate. Employee(s) were potentially exposed to electrical shock and/or fire hazard(s). In the following location(s): a) Golf Shop, outlet box near the computer b) Lagos Kitchen, outlet box near the Coffee Machine c) Main Bar, outlet box behind the True refrigerator Beer cooler d) Facilities bldg. 67177, outlet box on the right side of the black storage rack.
Recent events (2)
- — I (S) $4099
- — Z (S) $6831
1910.37 A03
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Golf Shop: On and/or before July 26, 2023, employee(s) would pass through the exit door to use the restrooms. Multiple items were stored along the path of the exit route leading to the restroom(s). This condition potentially exposed employee(s) to fire hazard(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Sep 25, 2023
- Abate by
- Oct 5, 2023
- Penalty
- Initial $959 · Current $574 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. On and/or before July 26, 2023, multiple fire extinguisher(s) were not mounted to the wall. This condition potentially exposed employee(s) to fire and/or smoke inhalation hazards. In the following location(s): a) Golf Shop b) Facilities Bldg. 67177
Recent events (2)
- — I (O) $574
- — Z (O) $959
More inspections at Desert Princess Home-Owners Association INC
View Desert Princess Home-Owners Association INC's full OSHA safety record →
More inspections in this industry (NAICS 713910)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346862709.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.