Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JGM, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JGM, INC. in 1201 VALLEY ROAD, COATESVILLE, PA 19320 (NAICS 238120). OSHA activity number 346868300.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JGM, INC. — free Get an email when a new federal OSHA severe-injury report for JGM, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JGM, INC.
Site address
1201 VALLEY ROAD
City
COATESVILLE
State
PA
ZIP
19320
Mailing
1201 VALLEY ROAD, COATESVILLE, PA 19320
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
90
Ownership type
A

2 citations on file for this inspection.

1910.334 A02 I

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Jan 23, 2024
Abate by
Mar 11, 2024
Penalty
Initial $14,518 · Current $9,000 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) JGM, Inc. Located at 1201 Valley Road, Coatesville, Pennsylvania- Fabrication Shop: On or about July 28, 2023, the employer did not ensure that flexible cord sets were inspected for external defects prior to each shift or use.  Employees used flexible cord sets with external defects including but not limited to damaged wire insulation and exposed wires, thereby exposing employees to electrical hazards.
Recent events (3)
  • — F (O) $9000
  • — C (S) $14518
  • — Z (S) $14518

1910.334 A02 II

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Jan 23, 2024
Abate by
Mar 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  a) JGM, Inc. Located at 1201 Valley Road, Coatesville, Pennsylvania- Fabrication Shop: On or about July 28, 2023, the employer did not ensure damaged flexible cord sets were removed from service.  Employees used flexible cord sets with external defects including but not limited to damaged wire insulation and exposed wires, thereby exposing employees to electrical hazards.