Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KAMPS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KAMPS INC. in 2132 REFUGEE ROAD, COLUMBUS, OH 43207 (NAICS 321920). OSHA activity number 346885007.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kamps INC. — free Get an email when a new federal OSHA severe-injury report for Kamps INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KAMPS INC.
Site address
2132 REFUGEE ROAD
City
COLUMBUS
State
OH
ZIP
43207
Mailing
2132 REFUGEE ROAD, COLUMBUS, OH 43207
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
70
Ownership type
A

6 citations on file for this inspection.

1910.178 N06

Serious Gravity 10 1 instance 70 exposed
Issued
Sep 15, 2023
Penalty
Initial $10,938 · Current $5,469 Reduced
29 CFR 1910.178(n)(6): The driver shall be required to look in the direction of, and keep a clear view of the path of travel.  a. On or about August 3, 2023, employees were not protected from being struck by forklifts while the forklift operators are pushing up to 4 stacks of pallets in the forward direction around the warehouse at a height that locks the vision of the operator.
Recent events (2)
  • — I (S) $5469
  • — Z (S) $10938

1910.212 A01

Serious Gravity 10 4 instances 11 exposed
Issued
Sep 15, 2023
Abate by
Sep 27, 2023
Penalty
Initial $10,938 · Current $5,469 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a. On or about August 3, 2023, located at the tear down line, employees were not protected from contacting the unused portion and the cutting portion of the blade on three Wood-Mizer PD200 Pallet dismantler band saws while the employees were dismantling wood pallets.  b. On or about August 3, 2023, located at the tear down line, employees who were sorting pallet pieces on the Trim Saw were exposed to an unguarded shear point between the pallet pieces, the conveyor teeth and the jig block mounted on the surface of the table.
Recent events (2)
  • — I (S) $5469
  • — Z (S) $10938

1910.213 R04

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 15, 2023
Abate by
Sep 27, 2023
Penalty
Initial $7,813 · Current $3,907 Reduced
29 CFR 1910.213(r)(4): The mention of specific machines in paragraphs (a) thru (q) and this paragraph (r) of this section, inclusive, is not intended to exclude other woodworking machines from the requirement that suitable guards and exhaust hoods be provided to reduce to a minimum the hazard due to the point of operation of such machines.  a. On or about August 3, 2023, located against the eastern wall on the north end of the warehouse, employees were not protected from contacting the blade of the company manufactured chop saw as a result of a four inch square hole in the lower section of the hood guard facing the operator.  b. On or about August 3, 2023, located approximately 15 feet east of the office complex in the warehouse, employees were not protected from contacting the blade of the company manufactured chop saw as a result of a four inch square hole in the lower section of the hood guard facing the operator.
Recent events (2)
  • — I (S) $3906.5
  • — Z (S) $7813

1910.219 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 15, 2023
Abate by
Sep 27, 2023
Penalty
Initial $9,376 · Current $4,688 Reduced
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.  a. On or about August 3, 2023, employees were not protected from contacting a rotating shaft with an exposed keyway while working within 6 inches of the exposed shaft projecting from the rear side of the electric motor on the northernmost Wood-Mizer PD200 Pallet dismantler band saw.
Recent events (2)
  • — I (S) $4688
  • — Z (S) $9376

1910.253 B02 IV

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Sep 27, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.  a. On or about August 3, 2023, employees were not protected from explosive and projectile hazards as a result of Oxygen and Acetylene tanks used for cutting metal were placed in storage in the maintenance shop without removing the regulators and placement of the valve protection caps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

1910.305 G01 IV A

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 15, 2023
Abate by
Sep 27, 2023
Penalty
Initial $7,813 · Current $3,907 Reduced
29 CFR 1910.305(g)(1)(iv):Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:  29 CFR  1910.305(g)(1)(iv)(A):As a substitute for the fixed wiring of a structure;  a. On or about August 3, 2023, employees were exposed to electrical shock and fire hazards while working at the miter saw cutting station due as a result of an extension cord used to provide 120 VAC power to the station. The temporary wiring was in use as fixed wiring.
Recent events (2)
  • — I (S) $3906.5
  • — Z (S) $7813

View Kamps INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346885007.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.