Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GGC NATIONAL CONTRACTORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GGC NATIONAL CONTRACTORS in 6391 CARLISLE PIKE, MECHANICSBURG, PA 17050 (NAICS 238390). OSHA activity number 346917867.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GGC National Contractors — free Get an email when a new federal OSHA severe-injury report for GGC National Contractors is published. One employer, no account, unsubscribe in one click.
Site address
6391 CARLISLE PIKE
City
MECHANICSBURG
State
PA
ZIP
17050
Mailing
3442 BABCOCK BOULEVARD SUITE B, PITTSBURGH, PA 15237
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 2 instances 1 exposed
Issued
Aug 31, 2023
Penalty
Initial $6,250 · Current $4,688 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a.  GC Desk - On or about August 17, 2023, the employer was using a relocatable power tap (surge protector/ power strip) at a construction site which is prohibited by UL listing and labeling for products XBYS.  b. GC Desk - On or about August 17, 2023, the employer had an extension cord plugged into a relocatable power tap essentially daisy chaining as defined by the UL listing and labeling for the power tap.  Corrected During Inspection
Recent events (2)
  • — I (S) $4687.5
  • — Z (S) $6250

1926.405 A02 II I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 31, 2023
Penalty
Initial $6,250 · Current $4,688 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:   a.  GC Desk - On or about August 17, 2023, the temporary electrical used to power the receptacle box next to GC's desk was damaged with cuts through the external insulation.   Corrected During Inspection
Recent events (2)
  • — I (S) $4687.5
  • — Z (S) $6250

View GGC National Contractors's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346917867.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.