Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EUREKA RESOURCES LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of EUREKA RESOURCES LLC in 34640 RTE 6, WYSOX, PA 18854 (NAICS 213112). OSHA activity number 346930779.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eureka Resources LLC — free Get an email when a new federal OSHA severe-injury report for Eureka Resources LLC is published. One employer, no account, unsubscribe in one click.
Site address
34640 RTE 6
City
WYSOX
State
PA
ZIP
18854
Mailing
34640 RTE 6, WYSOX, PA 18854
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
213112
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.212 B

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 3, 2023
Penalty
Initial $5,156 · Current $3,625 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  a) Maintenance Area Bench Grinder- On or about August 22, 2023, employees were exposed to caught in hazards from a bench grinder that was not securely anchored to the work bench to prevent walking or moving.  CORRECTED DURING INSPECTION
Recent events (2)
  • — I (S) $3625
  • — Z (S) $5156

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 3, 2023
Abate by
Nov 16, 2023
Penalty
Initial $5,156 · Current $3,625 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Crystallizer Roof- On or about August 22, 2023, employees were exposed to electrical shock hazards from a Flo switching adapter labeled for indoor use being utilized in an outdoor setting to power a camera.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3625
  • — Z (S) $5156

View Eureka Resources LLC's full OSHA safety record →