Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONAGRA BRANDS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CONAGRA BRANDS, INC. in W8880 COUNTY ROAD X, DARIEN, WI 53114 (NAICS 311411). OSHA activity number 346951494.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Conagra Brands, INC. — free Get an email when a new federal OSHA severe-injury report for Conagra Brands, INC. is published. One employer, no account, unsubscribe in one click.
Site address
W8880 COUNTY ROAD X
City
DARIEN
State
WI
ZIP
53114
Mailing
W8880 COUNTY ROAD X, DARIEN, WI 53114
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311411
Employees
810
Ownership type
A

4 citations on file for this inspection.

1910.178 G02

Serious Gravity 5 1 instance 50 exposed
Issued
Jan 9, 2024
Penalty
Initial $10,436 · Current $7,305 Reduced
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:  On or about August 31, 2023, the employer failed to ensure that charging apparatuses were protected from truck damage. Employees recharge forklifts periodically throughout the day and those that used the charging station were exposed to electrical hazards.
Recent events (2)
  • — I (S) $7305.2
  • — Z (S) $10436

1910.178 A04

Other-than-serious 2 instances 50 exposed
Issued
Jan 9, 2024
Abate by
Jan 24, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  a) On or about August 31, 2023, the employer failed to obtain manufacturer approval for the Tygard Claw attachment(s) prior to placing into service. According to the Tygard Claw's name plate the rated capacity was 2,000lbs lowering the forklift's 24in center load capacity by approximately 1,200lbs.   b) On or about August 31, 2023, the employer failed to obtain manufacturer approval for the fork extender attachment prior to placing into service. The forklift extension's rating guide indicate that a 24in truck rated capacity at 24in load center of 4,000lbs is reduced to 1,900lbs at a 48in load center.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 A05

Other-than-serious 2 instances 50 exposed
Issued
Jan 9, 2024
Abate by
Jan 24, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:  a) On or about August 31, 2023, the employer failed to obtain manufacturer approval and new data plate for the Tygard Claw attachment(s) prior to placing into service. According to the Tygard Claw's name plate the rated capacity was 2,000lbs lowering the forklift's 24in center load capacity by approximately 1,200lbs.   b) On or about August 31, 2023, the employer failed to obtain manufacturer approval and new data plate for the fork extender attachment prior to placing into service. The forklift extension's rating guide indicate that a 24in truck rated capacity at 24in load center of 4,000lbs is reduced to 1,900lbs at a 48in load center.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 50 exposed
Issued
Jan 9, 2024
Abate by
Jan 24, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about August 31, 2023, extension cords were used as a substitute for fixed wiring of industrial fans within the dock. Reliance on extension cords exposed employees to potential slip/trip and electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Conagra Brands, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346951494.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.