DARIEN, WI —
OSHA Inspection: CONAGRA BRANDS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CONAGRA BRANDS, INC. in W8880 COUNTY ROAD X, DARIEN, WI 53114 (NAICS 311411). OSHA activity number 346951494.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONAGRA BRANDS, INC.
- Site address
- W8880 COUNTY ROAD X
- City
- DARIEN
- State
- WI
- ZIP
- 53114
- Mailing
- W8880 COUNTY ROAD X, DARIEN, WI 53114
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311411
- Employees
- 810
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 G02
- Issued
- Jan 9, 2024
- Penalty
- Initial $10,436 · Current $7,305 Reduced
General-duty citation text
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks: On or about August 31, 2023, the employer failed to ensure that charging apparatuses were protected from truck damage. Employees recharge forklifts periodically throughout the day and those that used the charging station were exposed to electrical hazards.
Recent events (2)
- — I (S) $7305.2
- — Z (S) $10436
1910.178 A04
- Issued
- Jan 9, 2024
- Abate by
- Jan 24, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) On or about August 31, 2023, the employer failed to obtain manufacturer approval for the Tygard Claw attachment(s) prior to placing into service. According to the Tygard Claw's name plate the rated capacity was 2,000lbs lowering the forklift's 24in center load capacity by approximately 1,200lbs. b) On or about August 31, 2023, the employer failed to obtain manufacturer approval for the fork extender attachment prior to placing into service. The forklift extension's rating guide indicate that a 24in truck rated capacity at 24in load center of 4,000lbs is reduced to 1,900lbs at a 48in load center.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 A05
- Issued
- Jan 9, 2024
- Abate by
- Jan 24, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) On or about August 31, 2023, the employer failed to obtain manufacturer approval and new data plate for the Tygard Claw attachment(s) prior to placing into service. According to the Tygard Claw's name plate the rated capacity was 2,000lbs lowering the forklift's 24in center load capacity by approximately 1,200lbs. b) On or about August 31, 2023, the employer failed to obtain manufacturer approval and new data plate for the fork extender attachment prior to placing into service. The forklift extension's rating guide indicate that a 24in truck rated capacity at 24in load center of 4,000lbs is reduced to 1,900lbs at a 48in load center.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jan 9, 2024
- Abate by
- Jan 24, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about August 31, 2023, extension cords were used as a substitute for fixed wiring of industrial fans within the dock. Reliance on extension cords exposed employees to potential slip/trip and electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Conagra Brands, INC.
View Conagra Brands, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311411)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346951494.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.