LAONA, WI —
OSHA Inspection: WD FLOORING LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WD FLOORING LLC in 4852 ELM STREET, LAONA, WI 54541 (NAICS 321918). OSHA activity number 346956873.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WD FLOORING LLC
- Site address
- 4852 ELM STREET
- City
- LAONA
- State
- WI
- ZIP
- 54541
- Mailing
- P.O. BOX 368, LAONA, WI 54541
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 5
- Ownership type
- A
Citations
10 citations on file for this inspection.
1903.19 D01
- Issued
- May 15, 2025
- Abate by
- Jun 13, 2025
- Penalty
- Initial $1,023 · Current $1,023
General-duty citation text
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. The employer has not certified to OSHA, and provided documentation, that the hazardous conditions identified in Citations 1-3-a, 1-3-b, 1-3-c of this inspection have been corrected including the methods taken to correct the hazardous conditions.
Recent events (1)
- — Z (O) $1023
1910.106 D05 I
- Issued
- Feb 28, 2024
- Abate by
- Mar 27, 2024
- Penalty
- Initial $8,873 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.106(d)(5)(i): Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people. At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about September 13, 2023, to November 1, 2023, along the south wall to the left of the emergency exit door; two 55-gallon steel drums of n-butyl acetate were stored in a manner that limited safe egress through the emergency exit door, exposing employees to fire and burn hazards.
Recent events (3)
- — F (S) $5000
- — C (S) $8873
- — Z (S) $8873
1910.106 E06 II
- Issued
- Feb 28, 2024
- Abate by
- Mar 27, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with. At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about September 13, 2023, to November 1, 2023, at an establishment located at 4852 Elm Street in Laona, Wisconsin: the employer did not ensure the steel, 55-gallon drum containing n-butyl acetate was grounded and bonded prior to employees pumping the category 3 flammable liquid into a 1-gallon metal can, exposing employees to fire and burn hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Feb 28, 2024
- Abate by
- Mar 27, 2024
- Penalty
- Initial $8,873 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Where respirator use is not required: An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section. At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about October 27, 2023, to November 1, 2023, an employee was not provided training as outlined in the "Information for Employees Using Respirators When Not Required Under the Standard" while utilizing a Kischers 6200 half-face elastomeric respirator to protect against organic vapors and overspray while spray staining wood flooring products. b) On or about November 1, 2023, employees were not provided training as outlined in the "Information for Employees Using Respirators When Not Required Under the Standard" while utilizing Uline N95 respirators (Model: S-19252) to protect against overspray while spray staining wood flooring products.
Recent events (3)
- — F (S) $5000
- — C (S) $8873
- — Z (S) $8873
1910.134 C02 II
- Issued
- Feb 28, 2024
- Abate by
- Mar 27, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): Where respirator use is not required: In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks). At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about October 27, 2023, to November 1, 2023, the employer did not establish and implement those elements of a written respiratory protection program necessary to ensure that an employee wearing a Kischers 6200 half-face elastomeric respirator equipped with organic vapor cartridges was medically able to use the respirator, and that the respirator was cleaned, stored, and maintained so that its use did not present a health hazard to the user.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 D01 III
- Issued
- Feb 28, 2024
- Abate by
- May 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH. At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about October 27, 2023, to November 1, 2023, the employer did not conduct an evaluation of the workplace that included a reasonable estimation of employee exposures to respiratory hazards while spray finishing hardwood flooring, manually applying finishes, and cleaning equipment.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Feb 28, 2024
- Abate by
- Dec 31, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about October 27, 2023, to November 1, 2023, the employer did not provide a medical evaluation to determine an employee's ability to use a tight-fitting, Kischers 6200 half-face elastomeric respirator equipped with organic vapor cartridges while spray staining hardwood flooring planks and cleaning machines and equipment with n-butyl acetate.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Feb 28, 2024
- Abate by
- Apr 1, 2025
- Penalty
- Initial $12,421 · Current $9,000 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about September 5, 2023, to November 1, 2023, the employer did not implement and maintain a hazard communication program (HAZCOM) for hazardous chemicals used and present in the workplace, including, but not limited to, Barsol butyl acetate, Rubio Monocoat Smoke, Rubio Monocoat Oil Plus 2C (component A & B), Rubio Monocoat Fumed, Rubio Monocoat Oil UV (component A & B), Fremont propylene glycol, Sunnyside VM&P Naptha, combustible wood dust, and liquid petroleum gas (LPG).
Recent events (3)
- — F (S) $9000
- — C (S) $12421
- — Z (S) $12421
1910.1200 H02
- Issued
- Feb 28, 2024
- Abate by
- Apr 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(2): Employee information and training. Employees shall be informed of: (i) The requirements of this section; (ii) Any operations in their work area where hazardous chemicals are present; and (iii) The location and availability of the written hazard communication program, including the required list(s) of hazardous chemicals, and safety data sheets required by this section. At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about September 5, 2023, to November 1, 2023, the employer did not inform employees of the requirements of the Hazard Communication section, did not inform employees of the hazardous chemicals present in their work areas, and did not inform employees on the location and availability of safety data sheets when employees worked with hazardous chemicals used and present in the workplace including, but not limited to, Barsol butyl acetate, Rubio Monocoat Smoke, Rubio Monocoat Oil Plus 2C (component A & B), Rubio Monocoat Fumed, Rubio Monocoat Oil UV (component A & B), Fremont propylene glycol, Sunnyside VM&P Naptha, combustible wood dust, and liquid petroleum gas (LPG).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H03
- Issued
- Feb 28, 2024
- Abate by
- Apr 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3): Employee information and training. Employee training shall include at least the topics from (h)(3)(i) through (h)(3)(iv) of this section. At an establishment located at 4852 Elm Street in Laona, Wisconsin: a) On or about September 5, 2023, to November 1, 2023, the employer did not provide training to employees regarding: (i) how employees could detect hazardous chemicals in the work areas; (ii) the physical hazards, health hazards and combustible dust hazards of the chemicals in their work areas; (iii) the measures employees could take to protect themselves from hazardous chemicals through procedures and/or personal protective equipment (PPE); and (iv) the details of a hazard communication program including descriptions of labeling on containers and safety data sheets (SDS). Employees worked with hazardous chemicals such as, but not limited to, Barsol butyl acetate, Rubio Monocoat Smoke, Rubio Monocoat Oil Plus 2C (component A & B), Rubio Monocoat Fumed, Rubio Monocoat Oil UV (component A & B), Fremont propylene glycol, Sunnyside VM&P Naptha, combustible wood dust, and liquid petroleum gas (LPG).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at WD Flooring LLC
View WD Flooring LLC's full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346956873.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.