LINCOLN, NH —
OSHA Inspection: BURNDY LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BURNDY LLC in 34 BERN DIBNER DRIVE, LINCOLN, NH 03251 (NAICS 334417). OSHA activity number 346983414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BURNDY LLC
- Site address
- 34 BERN DIBNER DRIVE
- City
- LINCOLN
- State
- NH
- ZIP
- 03251
- Mailing
- 34 BERN DIBNER DRIVE, LINCOLN, NH 03251
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334417
- Employees
- 229
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 C
- Issued
- Jan 29, 2024
- Penalty
- Initial $11,524 · Current $11,524
General-duty citation text
29 CFR 1910.22(c): The employer did not provide, and ensure each employee uses, a safe means of access and egress to and from walking-working surfaces. Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee entering the plating tank was not provided with a safe means of entry or egress from the tank which was approximately 45 inches deep.
Recent events (1)
- — Z (S) $11524
1910.124 I02
- Issued
- Jan 29, 2024
- Penalty
- Initial $16,131 · Current $16,131
1860
General-duty citation text
29 CFR 1910.124(i)(2): An employee was permitted to clean the interior of the dip tank before pockets where hazardous vapors may have accumulated were ventilated and cleared:(a) Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee entered the Brite Dip tank on the automated plating line when it had not been ventilated to remove nitric acid and nitric oxide vapors.
Recent events (1)
- — Z (S) $16131
1910.132 D01 I
- Issued
- Jan 29, 2024
- Penalty
- Initial $11,524 · Current $11,524
1860
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee was exposed to dermal contact with nitric acid containing sludge when entering the Brite Dip tank to clean out sludge and retrieve parts. The employer did not select the appropriate PPE when they provided the employee with Tyvek 400 suits that are not rated to protect from chemical exposure.
Recent events (1)
- — Z (S) $11524
1910.134 D01 III
- Issued
- Jan 29, 2024
- Penalty
- Initial $16,131 · Current $16,131
1860
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee entering the Brite dip plating tank was not protected from inhalation of nitric acid and nitric oxide where the employer did not evaluate the respiratory hazard and require the use of respiratory protection.
Recent events (1)
- — Z (S) $16131
1910.146 C01
- Issued
- Jan 29, 2024
- Penalty
- Initial $16,131 · Current $16,131
1860
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, the Brite Dip tank on the Automated Plating Line was not evaluated and identified as a permit-required confined space prior to an employee entering the space to complete cleanout work.
Recent events (1)
- — Z (S) $16131
1910.146 C02
- Issued
- Jan 29, 2024
- Penalty
- Initial $0 · Current $0
1860
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, employees entering the Brite Dip tank to clean out sludge were not informed by signage or other means that the tank was a permit required confined space.
Recent events (1)
- — Z (S) $0
1910.146 D01
- Issued
- Jan 29, 2024
- Penalty
- Initial $0 · Current $0
1860
General-duty citation text
29 CFR 1910.146(d)(1): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not implement the measures necessary to prevent unauthorized entry: Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee entered the Brite Dip tank, a permit required confined space when the employer did not implement measures to prevent unauthorized entry.
Recent events (1)
- — Z (S) $0
1910.146 E01
- Issued
- Jan 29, 2024
- Penalty
- Initial $0 · Current $0
1860
General-duty citation text
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit: Note: Appendix D to 29 CFR 1910.146 presents examples of permits whose elements are considered to comply with these requirements. Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee entered the Brite Dip tank, a permit required confined space. An entry permit was not completed prior to the employee entering the confined space.
Recent events (1)
- — Z (S) $0
1910.146 G01
- Issued
- Jan 29, 2024
- Penalty
- Initial $16,131 · Current $16,131
1860
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:(a) Location: Automated Plating Line, Brite Dip Tank On or about, September 15, 2023, an employee entered the Brite Dip tank, a permit required confined space to clean out sludge and fallen parts. The employee had not been trained on how to safely perform duties while entering permit required confined spaces.
Recent events (1)
- — Z (S) $16131
More inspections at Burndy LLC
View Burndy LLC's full OSHA safety record →
More inspections in this industry (NAICS 334417)
More inspections in NH
Source