Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BOWLERO TALKING STICK LANE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOWLERO TALKING STICK LANE, LLC in 9139 TALKING STICK WAY, SCOTTSDALE, AZ 85250 (NAICS 713950). OSHA activity number 346986482.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bowlero Talking Stick Lane, LLC — free Get an email when a new federal OSHA severe-injury report for Bowlero Talking Stick Lane, LLC is published. One employer, no account, unsubscribe in one click.
Site address
9139 TALKING STICK WAY
City
SCOTTSDALE
State
AZ
ZIP
85250
Mailing
ATTN: JP MULLAN 9139 TALKING STICK WAY, SCOTTSDALE, AZ 85250
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713950
Employees
103
Ownership type
A

4 citations on file for this inspection.

1910.253 B02 II

Other-than-serious Gravity 1 1 instance 14 exposed
Issued
Oct 17, 2023
Penalty
Initial $5,692 · Current $3,984 Reduced
29 CFR  1910.253(b)(2)(ii):Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  KITCHEN:  Employees were exposed to struck-by hazards where two compressed gas cylinders were not secured from being knocked over.
Recent events (3)
  • — F (O) $3984.4
  • — C (S) $5692
  • — Z (S) $5692

1910.253 B02 IV

Other-than-serious Gravity 1 1 instance 14 exposed
Issued
Oct 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  KITCHEN: Employees were exposed to struck-by hazards where two compressed gas cylinders were stored without protective caps.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 B02

Other-than-serious Gravity 1 2 instances 9 exposed
Issued
Oct 17, 2023
Penalty
Initial $5,692 · Current $0 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  BAR: Employees were exposed to fire and electrical hazards where a 15Amp relocatable power tap was connected in series with a flexible extension cord to power two 8Amp rope light strands and a 3.8Amp glass froster.
Recent events (3)
  • — F (O) $0
  • — C (S) $5692
  • — Z (S) $5692

1910.305 A02 I B

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Oct 17, 2023
Penalty
Initial $5,692 · Current $3,984 Reduced
29 CFR  1910.305(a)(2)(i)(B):Temporary wiring was used for a period exceeding 90 days.  ELECTRICAL ROOM: Employees were exposed to fire hazards where a flexible cord was used for permanent wiring to provide power to an air compressor for approximately six months.
Recent events (3)
  • — F (O) $3984.4
  • — C (S) $5692
  • — Z (S) $5692