OSHA Inspection: DYNA-MIX, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DYNA-MIX, INC. in 701 S. LYONS, TYLER, TX 75703 (NAICS 326299). OSHA activity number 346999337.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dyna-Mix, INC. — free Get an email when a new federal OSHA severe-injury report for Dyna-Mix, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DYNA-MIX, INC.
Site address
701 S. LYONS
City
TYLER
State
TX
ZIP
75703
Mailing
701 S. LYONS, TYLER, TX 75703
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
60
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2024
Abate by
May 16, 2024
Penalty
Initial $14,518 · Current $8,719 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) This violation occurred on or about September 14, 2023, in the production plant; where procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were clearing rubber jam under cutter on Wig Wag machine, line #1 without lockout tagout,  were exposed to amputation hazards.
Recent events (2)
  • — I (S) $8718.8
  • — Z (S) $14518

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 28, 2024
Abate by
May 16, 2024
Penalty
Initial $10,372 · Current $5,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about September 14,  2023, and at times prior thereto, the employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and requirements of this standard were followed.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $10372

1910.147 C07 I A

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2024
Abate by
May 16, 2024
Penalty
Initial $14,518 · Current $8,719 Reduced
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   a) This violation occurred on or about September 14, 2023, and at times prior thereto; the employer did not ensure that employees performing servicing, unjamming rubbers under cuter on the wig wang machine, were trained in the purpose and use of the energy control procedure. Employees were exposed to amputation hazards.
Recent events (2)
  • — I (S) $8718.8
  • — Z (S) $14518

1910.147 C07 I B

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2024
Abate by
May 16, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:  a) This violation occurred on or about September 14, 2023, and at times prior thereto; the employer did not ensure that effected employees, who were unjamming rubbers under cuter on the wig wag machine, were instructed in the purpose and use of the energy control procedure. Employees were exposed to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 28, 2024
Penalty
Initial $8,816 · Current $5,290 Reduced
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  a) This violation was observed on or about September 25, 2023; in the production plant, where portable fire extinguishers were missing.
Recent events (2)
  • — I (S) $5289.6
  • — Z (S) $8816

1910.212 A01

Repeat Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2024
Abate by
May 16, 2024
Penalty
Initial $29,036 · Current $17,422 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a) This violation occurred on or about September 25, 2023, and at times prior thereto; in production plant, line #1 wig wag, where employees were exposed to being caught-in the unguarded pinch points created by conveyor, rotating shafts and pillar bearings.  The Dyna-Mix Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1645866, citation number 1, item number 1 and was affirmed as a final order on 06/13/2023, with respect to a workplace located at 701 S. Lyons, Tyler, TX 75703.
Recent events (2)
  • — I (R) $17421.6
  • — Z (R) $29036

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Feb 28, 2024
Abate by
May 16, 2024
Penalty
Initial $10,372 · Current $4,851 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours:  a) This violation occurred on or about September 19, 2023, when the employer failed to report to OSHA within twenty-four (24) hours the hospitalization of an employee from work-related injury that occurred on September 14, 2023.