OSHA Inspection: DEFLECTO, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DEFLECTO, LLC in 303 OXFORD STREET, DOVER, OH 44622 (NAICS 326130). OSHA activity number 347023665.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Deflecto, LLC — free Get an email when a new federal OSHA severe-injury report for Deflecto, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DEFLECTO, LLC
Site address
303 OXFORD STREET
City
DOVER
State
OH
ZIP
44622
Mailing
303 OXFORD STREET, DOVER, OH 44622
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326130
Employees
87
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 23, 2024
Abate by
Mar 14, 2024
Penalty
Initial $11,292 · Current $11,292
1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a.  On or about September 23, 2023, the employer did not document specific procedures for the control of potentially hazardous energy related to the Early Warning Triangle machine.
Recent events (2)
  • — I (S) $11292
  • — Z (S) $11292

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Feb 23, 2024
Abate by
Mar 14, 2024
Penalty
Initial $11,292 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a.  On or about September 23, 2023, authorized employees did not receive training in the recognition of and means and methods to control hazardous energy sources related to the Early Warning Triangle machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

1910.147 D

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 23, 2024
Abate by
Mar 14, 2024
Penalty
Initial $11,292 · Current $11,292
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence as required by 1910.147(d)(1) through (d)(6):   a. On or about September 23, 2023, employees were exposed to machine pinch point hazards when performing servicing and maintenance covered activities on the Early Warning Triangle machine. The employer did not ensure that energy control application steps were implemented as the machine was not shut down or turned off.
Recent events (2)
  • — I (S) $11292
  • — Z (S) $11292

View Deflecto, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347023665.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.