ALLOY, WV —
OSHA Inspection: WVA MANUFACTURING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WVA MANUFACTURING, LLC in US ROUTE 60 EAST, ALLOY, WV 25002 (NAICS 331410). OSHA activity number 347028003.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WVA MANUFACTURING, LLC
- Site address
- US ROUTE 60 EAST
- City
- ALLOY
- State
- WV
- ZIP
- 25002
- Mailing
- P.O. BOX 248, ALLOY, WV 25002
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331410
- Employees
- 250
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D03
- Issued
- Dec 7, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $10,046 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (a) #7 Silo 2nd Floor: On October 5, 2023, and times prior to, employees attempting to correct a plugging issue on the #7 silo did not de-energize the screw conveyor auger motor using the energy isolating device, exposing employees to two moving belts and two rotating sheaves.
Recent events (2)
- — I (S) $0
- — Z (S) $10046
1910.147 D04 I
- Issued
- Dec 7, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $0 · Current $10,046
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) #7 Silo 2nd Floor: On October 5, 2023, and times prior to, employees attempting to correct a plugging issue on the #7 silo did not affix a lockout or tagout device to the screw conveyor auger motor energy isolating device, exposing employees to two moving belts and two rotating sheaves.
Recent events (2)
- — I (S) $10046
- — Z (S) $0
More inspections at WVA Manufacturing, LLC
View WVA Manufacturing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331410)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347028003.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.