CABAZON, CA —
OSHA Inspection: BLUETRITON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BLUETRITON in 14020 ELM ST, CABAZON, CA 92230 (NAICS 312112). OSHA activity number 347028466.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BLUETRITON
- Site address
- 14020 ELM ST
- City
- CABAZON
- State
- CA
- ZIP
- 92230
- Mailing
- 14020 ELM ST, CABAZON, CA 92230
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312112
- Employees
- 172
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.138 A
- Issued
- Nov 15, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $5,692 · Current $3,131 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion: Maintenance Room: On and/or before October 10, 2023, employee(s) used a Wilton Model: 4210 to smooth out the edges for metal fabricated parts. The employer did not require employee(s) to use appropriate hand protection when operating the Wilton sander. Employee(s) were potentially exposed to lacerations and abrasions hazards.
Recent events (2)
- — I (O) $3131
- — Z (S) $5692
1910.242 B
- Issued
- Nov 15, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $7,590 · Current $4,175 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. Bottling Plant: On and/or before October 11, 2023, employee(s) used 100-110 p.s.i compressed air to clean bottling lines. The P.S.I was not reduced to less than 30 p.s.i. This condition potentially exposed employee(s) to cutaneous or subcutaneous laceration(s)/embolism hazard(s).
Recent events (2)
- — I (S) $4175
- — Z (S) $7590
1910.303 B02
- Issued
- Nov 15, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $11,385 · Current $6,262 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On and/or about October 11, 2023, employee(s) used a Dayton Commercial Oscillating fan to circulate air and a yellow extension cord to power a Lenovo laptop . The fan and extension cord was not used according to listing or labeling instructions. In the following locations: a) Filler Labeler Area, line one: a Dayton Commercial Oscillating fan b) Maintenance Room: yellow flexible extension cord Employee(s) were potentially exposed to fire/electrical shock hazard(s).
Recent events (2)
- — I (S) $6262
- — Z (S) $11385
1910.305 G02 III
- Issued
- Nov 15, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Filler Labeler Area, line one: On and/or about October 11, 2023, a Dayton Commercial Oscillating fan to circulate air in the area. The fan was plugged into a white Staples power strip and had exposed wire at the end of the wire next to the plug. Employee(s) were potentially exposed to fire/electrical shock hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.140 C18
- Issued
- Nov 15, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.140(c)(18): The employer did not ensure that personal fall protection systems are inspected before initial use during each work shift for mildew, wear, damage, and other deterioration, and defective components are removed from service. Bottling Floor: On and/or before October 10, 2023, employee(s) used personal fall protection and life lines to work above 4 feet with a boom and/or scissor lift. The employer did not ensure that life lines such as shock absorbers that were defective were removed from service and were inspected before initial service. Employee(s) were exposed to fall hazard(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.140 C21
- Issued
- Nov 15, 2023
- Abate by
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.140(c)(21): The employer did not provide for prompt rescue of each employee in the event of a fall. Bottling Facility: On and/or before October 10,2023, employee(s) used personal fall protection and life lines to work above 4 feet with a boom and/or scissor lift. In the event of a fall the employer did not provide for prompt rescue of each employee. Employee(s) were potentially exposed to orthostatic intolerance hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Nov 15, 2023
- Abate by
- Dec 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Maintenance Room, Welding equipment: On and/or before October 10, 2023, fire extinguisher(s) were not mounted to the wall. Unmounted fire extinguisher(s) may cause a delayed response and/or inability to locate during an emergency. This condition potentially exposed employee(s) to fire and/or smoke inhalation hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Nov 15, 2023
- Abate by
- Dec 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: Maintenance Room, next to the rebuild tooling cabinet: On and/or before October 11, 2023, the employer did not ensure at least 3 feet in front of the electrical panel and switch box was clear. The circuit breaker had a tool cabinet and clothing obstructing the panel. This condition interferes with access and immediate shutdown of a circuit in the panel, particularly in the event of an emergency. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Bluetriton
View Bluetriton's full OSHA safety record →
More inspections in this industry (NAICS 312112)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347028466.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.