BYRON, CA —
OSHA Inspection: BUREAU OF RECLAMATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BUREAU OF RECLAMATION in 16650 KELSO RD, BYRON, CA 94514 (NAICS 221111). OSHA activity number 347031049.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUREAU OF RECLAMATION
- Site address
- 16650 KELSO RD
- City
- BYRON
- State
- CA
- ZIP
- 94514
- Mailing
- 16650 KELSO RD, BYRON, CA 94514
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221111
- Employees
- 5
- Ownership type
- D
Citations
7 citations on file for this inspection.
1910.22 A01
- Issued
- Dec 18, 2023
- Abate by
- Jan 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): Passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition. In the main work area, electrical room workshop, and storage area of the maintenance shop, the floor was not kept clear and orderly, creating slip, trip, and fall work hazards. Employees were exposed to broken bone injuries.
Recent events (1)
- — Z (S) $0
1910.37 A03
- Issued
- Dec 18, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3):Exit routes were not free and unobstructed. Materials or equipment were placed within the exit route. In the electrical room workshop, the exit route leading the door on the east side of the building was obstructed by various equipment. Employees were exposed to burns, smoke inhalation, and tripping hazards.
Recent events (1)
- — Z (S) $0
1910.37 B06
- Issued
- Dec 18, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): An exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source. In the electrical room workshop, the 2 exit signs above the man doors along the exit route heading east were not illuminated as required. Employees were exposed to hazards related to emergency evacuation.
Recent events (1)
- — Z (S) $0
1910.305 G01 III
- Issued
- Dec 18, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): A flexible cord was not energized from an approved receptacle. In office #7 on the first floor of the main admin building, a black extension cord was not plugged into an approved receptable outlet. This cord was plugged into an orange extension cord. Employees were exposed to smoke inhalation hazards.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Dec 18, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): A flexible cord was used as a substitute for the fixed wiring of a structure. In office #7 on the first floor of the main admin building, a black flexible extension cord was found being used as a substitute for the fixed wiring of a structure. The cord was plugged into another orange cord leading to an outlet.
Recent events (1)
- — Z (O) $0
1910.157 E02
- Issued
- Dec 18, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2):Portable extinguishers were not visually inspected monthly. Main office building - In the kitchen and near the bathroom of the first floor, the fire extinguishers were not inspected monthly. Employees were exposed to smoke inhalation hazards.
Recent events (1)
- — Z (O) $0
1910.303 G01
- Issued
- Dec 18, 2023
- Abate by
- Dec 29, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. In the maintenance shop, on the east wall, next to an exit door, an electrical panel was observed to be blocked by a chair. Employees were exposed to smoke inhalation and fire hazards.
Recent events (1)
- — Z (O) $0
More inspections at Bureau of Reclamation
View Bureau of Reclamation's full OSHA safety record →
More inspections in this industry (NAICS 221111)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347031049.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.