WINTER GARDEN, FL —
OSHA Inspection: EAGLE REMODELING CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EAGLE REMODELING CONSTRUCTION, INC. in 17075 PORTER RD, WINTER GARDEN, FL 34787 (NAICS 238990). OSHA activity number 347036527.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAGLE REMODELING CONSTRUCTION, INC.
- Site address
- 17075 PORTER RD
- City
- WINTER GARDEN
- State
- FL
- ZIP
- 34787
- Mailing
- 1924 HAWKS VIEW DR, RUSKIN, FL 33570
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Jan 25, 2024
- Abate by
- Mar 13, 2024
- Penalty
- Initial $2,074 · Current $2,074
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a.) On or about October 16, 2023, employees were exposed to overhead struck by hazards, in that the employer allowed their employees to work underneath the scaffold without wearing hard hats while other employees were working above them.
Recent events (1)
- — Z (S) $2074
1926.451 H01
- Issued
- Jan 25, 2024
- Abate by
- Mar 13, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(1):Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall. a) On or about October 16, 2023, the employer allowed their employees to work beneath the scaffold while others worked above without having a system to prevent falling objects, exposing them to struck by hazards.
Recent events (1)
- — Z (S) $0
1926.451 C02
- Issued
- Jan 25, 2024
- Abate by
- Mar 13, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about October 16, 2023 the employer allowed their employees to work on a scaffold that did not have a base plates, exposing their employees to fall hazards.
Recent events (1)
- — Z (S) $4839
1926.451 E01
- Issued
- Jan 25, 2024
- Abate by
- Mar 13, 2024
- Penalty
- Initial $3,457 · Current $3,457
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about October 16, 2023, the employer allowed their employees to climb the scaffold frame as means of access, exposing them to fall hazards.
Recent events (1)
- — Z (S) $3457
1926.451 G01
- Issued
- Jan 25, 2024
- Abate by
- Mar 13, 2024
- Penalty
- Initial $3,457 · Current $3,457
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about October 16, 2023, the employer allowed their employees to work on a scaffold approximately 12 feet high without being protected by a guardrail system, exposing them to fall hazards.
Recent events (1)
- — Z (S) $3457
More inspections at Eagle Remodeling Construction, INC.
View Eagle Remodeling Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347036527.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.