Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: BEFESA ZINC US INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BEFESA ZINC US INC. in 2701 EAST 114TH STREET, CHICAGO, IL 60617 (NAICS 332999). OSHA activity number 347037418.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Befesa Zinc US INC. for free Get an email when a new federal OSHA severe-injury report for Befesa Zinc US INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BEFESA ZINC US INC.
Site address
2701 EAST 114TH STREET
City
CHICAGO
State
IL
ZIP
60617
Mailing
2701 EAST 114TH STREET, CHICAGO, IL 60617
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
74
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 8, 2023
Abate by
Jan 5, 2024
Penalty
Initial $11,162 · Current $11,162
29 CFR 1910.147(c)(7)(i)(A):  Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a.  On or about October 12, 2023, in BC-10 Screw Level Production, the employer failed to provide adequate training for employees performing service and/or maintenance activities, to ensure the knowledge and skills required for the safe application, usage and removal of energy control devices were acquired.   An employee sustained left index, middle and ring finger fractures leading to hospitalization as a result of S5 to S4 conveyor screw not being de-energized and lockout out during servicing and maintenance (unjamming product).   Employees were thereby exposed to the hazards associated with moving parts.
Recent events (1)
  • · Z (S) $11162

1910.147 D

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 8, 2023
Abate by
Jan 5, 2024
Penalty
Initial $11,162 · Current $11,162
29 CFR 1910.147(d):  The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6).  a.   On or about October 12, 2023, in the BC-10 Screw Level Production, an employee was exposed to machine hazards associated with rotating parts while performing service and maintenance (unjamming of product) on the S5 to S4 conveyor screw, which resulted in left index, middle and ring finger fractures leading to hospitalization.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
  • · Z (S) $11162

1910.147 C06 I

Other-than-serious 1 instance 10 exposed
Issued
Dec 8, 2023
Abate by
Jan 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  a.  On or about October 12, 2023, in the BC-10 Screw Level Production, employees were required to service and maintain S5 - S4 conveyor screw.  The employer did not conduct a periodic inspection of each energy control procedure at least annually to ensure that the procedure and the requirements of the standard were being followed.