Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRICAL INSTRUMENTATION CONTROL SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELECTRICAL INSTRUMENTATION CONTROL SERVICES in SHELL STATION CHALLON PAGO, ORDOT, GU 96910 (NAICS 238210). OSHA activity number 347045742.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electrical Instrumentation Control Services — free Get an email when a new federal OSHA severe-injury report for Electrical Instrumentation Control Services is published. One employer, no account, unsubscribe in one click.
Site address
SHELL STATION CHALLON PAGO
City
ORDOT
State
GU
ZIP
96910
Mailing
P.O. BOX 4918, HAGATNA, GU 96932
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.1153 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 31, 2024
Abate by
Feb 20, 2024
Penalty
Initial $2,074 · Current $2,074
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.  Shell Station Canopy Roof: Employees used a Milwaukee rotary hammer drill to drill holes into concrete without any control measures implemented from Table 1-Specified Exposure Control Methods When Working with Materials Containing Crystalline Silica. Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (S) $2074

1910.134 E01

Other-than-serious 1 instance 5 exposed
Issued
Jan 31, 2024
Abate by
Feb 27, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  Employees that were required to wear a N95 respirator while drilling concrete were not medically cleared for use. Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 5 exposed
Issued
Jan 31, 2024
Abate by
Feb 27, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  Employees that were required to wear a N95 respirator while drilling concrete were not fit tested prior to respirator use. Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (O) $0

View Electrical Instrumentation Control Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347045742.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.