MANGILAO, GU —
OSHA Inspection: HARMONY GUAM CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HARMONY GUAM CORPORATION in 531 SOUTH VIETNAM MEMORIAL HIGHWAY, MANGILAO, GU 96913 (NAICS 238110). OSHA activity number 347045791.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARMONY GUAM CORPORATION
- Site address
- 531 SOUTH VIETNAM MEMORIAL HIGHWAY
- City
- MANGILAO
- State
- GU
- ZIP
- 96913
- Mailing
- P.O. BOX 26279, BARRIGADA, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.303 B01
- Issued
- Jan 9, 2024
- Penalty
- Initial $1,707 · Current $1,195 Reduced
General-duty citation text
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section. Roadside of the building: A Makita angle grinder was used to cut rebar without a guard. Employees were exposed to laceration hazards.
Recent events (2)
- — I (S) $1194.9
- — Z (S) $1707
1926.405 A02 II J
- Issued
- Jan 9, 2024
- Abate by
- Jan 29, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not of the three-wire type: Roadside of the building: Multiple extension cords used to power a battery charger and power tools were not three-wire type. Employees were exposed to electrical and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1053 B04
- Issued
- Jan 9, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: Roadside of the building: A Werner 10-foot step ladder was used in the closed position to build concrete forms. Employees were exposed to fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Harmony Guam Corporation
View Harmony Guam Corporation's full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347045791.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.