Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OVERHEAD DOOR CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OVERHEAD DOOR CORPORATION in 1 DOOR DRIVE, MOUNT HOPE, OH 44660 (NAICS 332322). OSHA activity number 347048779.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Overhead Door Corporation — free Get an email when a new federal OSHA severe-injury report for Overhead Door Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1 DOOR DRIVE
City
MOUNT HOPE
State
OH
ZIP
44660
Mailing
P.O. BOX 67, MOUNT HOPE, OH 44660
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
415
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 36 exposed
Issued
Jan 12, 2024
Penalty
Initial $12,278 · Current $7,367 Reduced
29 CFR  1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.  On or about October 12, 2023, the employer did not document procedures for the control of potentially hazardous energy when employees performed service and maintenance activities on the WFL pressure conveyor.
Recent events (2)
  • — I (S) $7367
  • — Z (S) $12278

1910.147 D

Repeat Gravity 5 1 instance 8 exposed
Issued
Jan 12, 2024
Penalty
Initial $61,391 · Current $36,835 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6).  On or about October 12, 2023, employees were exposed to moving parts of the WFL pressure conveyor while performing maintenance and servicing activities such as but not limited to changeover. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147 (d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  The Overhead Door Corporation was previously cited for a violation of this Occupational Safety and Health standard 29 CFR 1910.147(d), which was contained in OSHA inspection number 1378859, citation number 1, item number 2b and was affirmed as a final order on May 16, 2019, with respect to a workplace located at 1295 E. Fairground, Marion, OH 43302.
Recent events (2)
  • — I (R) $36835
  • — Z (R) $61391

View Overhead Door Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347048779.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.