AURORA, CO —
OSHA Inspection: COLORADO COUNTER-TOPS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COLORADO COUNTER-TOPS, INC. in 3556 QUENTIN STREET, AURORA, CO 80011 (NAICS 327991). OSHA activity number 347052920.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLORADO COUNTER-TOPS, INC.
- Site address
- 3556 QUENTIN STREET
- City
- AURORA
- State
- CO
- ZIP
- 80011
- Mailing
- 3556 QUENTIN STREET, AURORA, CO 80011
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 48
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 19, 2023
- Abate by
- Jan 8, 2024
- Penalty
- Initial $3,984 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards: a) 3556 Quentin Street Aurora, CO 80011: On or around October 23, 2023, and at times prior, employees were exposed to a struck by hazards while working in and around storage racks that were not securely fastened to the floor. b) 3556 Quentin Street Aurora, CO 80011: On or around October 23, 2023, and at times prior, employees were exposed to a struck by hazards while working in and around storage racks that did not display a plaque designating load sizes.
Recent events (2)
- — I (S) $0
- — Z (S) $3984
1910.101 B
- Issued
- Dec 19, 2023
- Abate by
- Jan 8, 2024
- Penalty
- Initial $3,984 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): The employer did not ensure that the in-plant transfer, handling, storage, and use of acetylene in cylinders complied with the provisions of CGA Pamphlet G-1-2009 ("Acetylene"), which is incorporated by reference as specified in 29 CFR 1910.6: (a) On or around October 23, 2023, and at times prior, employees were exposed to fire and explosive hazards in that acetylene cylinders used for the cutting torch were not stored separately from the oxygen tanks.
Recent events (2)
- — I (O) $0
- — Z (S) $3984
1910.212 A01
- Issued
- Dec 19, 2023
- Abate by
- Jan 8, 2024
- Penalty
- Initial $3,984 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) 3556 Quentin Street Aurora, CO 80011 Storage room north of the production area: On or around October 23, 2023, and at times prior, employees were exposed to struck by hazards from flying chips and sparks while utilizing an unguarded Delta Drill Press (Model #8778, Serial #17-900).
Recent events (2)
- — I (O) $0
- — Z (S) $3984
More inspections at Colorado Counter-Tops, INC.